LACING THE BATTERY
R
EPLACING
T
HE
B
ATTERY
The MBK Series UPS has an easy to replace hot-swappable battery. Please read the
following warning statements before attempting to service the battery.
WARNING!
THIS UNINTERRUPTIBLE POWER SOURCE CONTAINS POTENTIALLY
HAZARDOUS VOLTAGES. DO NOT ATTEMPT TO DISASSEMBLE THE UNIT
BEYOND BATTERY REPLACEMENT PROCEDURES BELOW. EXCEPT FOR
THE BATTERY, THIS UPS CONTAINS NO USER SERVICABLE PARTS.
REPAIRS CAN BE PERFORMED BY MINUTEMAN SERVICE PERSONNEL
ONLY
DO NOT OPEN OR MUTILATE BATTERIES. RELEASED ELECTROLYTE
IS HARMFUL TO THE SKIN AND EYES AND MAY BE TOXIC
CAUTION:
CAUTION:
CAUTION:
THE BATTERIES IN THIS UPS ARE RECYCLABLE. DISPOSE OF THE
BATTERIES PROPERLY. THE BATTERIES CONTAIN LEAD AND POSE A
HAZARD TO THE ENVIRONMENT AND HUMAN HEALTH IF NOT DISPOSED
OF PROPERLY. REFER TO LOCAL CODES FOR PROPER DISPOSAL
REQUIREMENTS OR RETURN THE BATTERY TO MINUTEMAN.
ALTHOUGH BATTERY SYSTEM VOLTAGES ARE ONLY 12 VDC AND 24
VDC THE BATTERY SYSTEM CAN STILL PRESENT A RISK. THE
CURRENT CAPABILITY OF A BATTERY IS SUFFICENT TO BURN WIRE
OR TOOLS VERY RAPIDLY, PRODUCING MOLTEN METAL. OBSERVE
THESE PRECAUTIONS WHEN REPLACING THE BATTERIES:
1. REMOVE WATCHES, RINGS, OR OTHER METAL OBJECTS;
2. USE HAND TOOLS WITH INSULATED HANDLES;
3. DO NOT LAY TOOLS OR OTHER METAL PARTS ON TOP OF
BATTERIES
REPLACE BATTERIES WITH THE SAME NUMBER AND TYPE AS
ORIGINALLY INSTALLED IN THE UPS. THESE BATTERIES HAVE
PRESSURE OPERATED VENTS.
CAUTION:
DO NOT DISPOSE OF BATTERIES IN A FIRE. THE BATTERIES MAY
EXPLODE.
.
4. Connect the new battery in place of the old one, ensuring that black wire is connected to
the negative (-) terminal and the red wire is connected to the positive (+) terminal. Small
sparks at the battery connection are normal.
5. Place the new battery in the case taking care not to pinch any wires.
6. Slide the battery door back into its slot and replace the retaining screw.
7. Dispose of the battery properly at an appropriate recycling facility or return it to the supplier
in
the packing material for the new battery. See new battery instructions for more info.
B
ATTERY
R
EPLACEMENT
P
ROCEDURE
PLEASE READ THE CAUTIONS SECTION BEFORE ATTMPTING TO REPLACE
THE BATTERIES
1. Lay the unit on its side or bring to the edge of a table.
Remove the retaining screw holding the
battery door in place and slide the door towards the
bottom of the unit.
2. Gently pull out the battery by grasping the battery removal
tab
3. Disconnect the two wires connecting the battery to the UPS. Pull back straight on the
connector while wiggling the connector from side to side.
pull
pull
connect
replace
disconnect
En-
glish
7
OBT
AINING SERVICE
I
F
T
HE
UPS
R
EQUIRES
S
ERVICE
1.Use the
TROUBLESHOOTING
section 5 to eliminate obvious causes.
2.Verify that no circuit breakers are tripped. A tripped circuit breaker is the most common
problem.
3.Call your dealer for assistance. If you cannot reach your dealer, or if he cannot resolve the
problem. call or FAX Minuteman Technical Support at the following numbers; Voice
phone
(972) 446-7363, FAX line (972) 446-9011. Please have the following information available
BEFORE calling technical support.
A. Your Name and address.
B. Where and when the unit was purchased.
C. All of the model information on the rear of your Pro Series UPS.
D. Any information on the failure, including LEDs that may be illuminated.
E. A description of the protected equipment, including model numbers if possible.
F. A technician will ask you for the above information and, if possible, help solve your
problem over the phone. In the event that the unit requires factory service, the
technician will issue you a Return Material Authorization Number (RMA #).
G. If the UPS is under warranty, the repairs will be done at no charge. If not, there will
be a charge for repair.
4. Pack the UPS in its original packaging. If the original packaging is no longer available, ask
the technical support technician about obtaining a new set. It is important to pack the UPS
properly in order to avoid damage in transit. Never use Styrofoam beads for a packing
material.
A. Include a letter with your name, address, day time phone number, RMA number, a
copy of your original sales receipt, and a brief description of the trouble.
5. Mark the RMA # on the outside of all packages. The factory cannot accept any package
without the RMA # marked on the outside.
6. Return the UPS by insured, prepaid carrier to:
Minuteman, Para Systems Inc.
1455 LeMay Drive
Carrollton, Tx. 75007
115 (230) VAC
50 or 60 Hz, +/-0 Hz, unless synchronized to utility during brownout
Simulate sine-wave
Overcurrent and short circuit protected, latching shutdown on overload
8
SPE
CIFICATIONS
3 to 6 years, depending on the number of discharge cycles and ambient temp.
2 to 5 hours from total discharge
<5%
<1%
50 or 60 Hz, autosensing
Resettable circuit breaker
50 or 60 Hz, +/-5%
2 - 4 ms typical
320VA
208W
520VA
338W
680VA
442W
500 J (440J)
19.5 kAmps total
500 J (440J)
39 kAmps total
0 ns (instantaneous) normal mode; <5 ns common mode
<5%
<0.5%
0 to 40 degrees C (+32 to 104 degrees F)
-15 to +45 degrees C (+5 to +113 degrees F)
0 to 95%, non-condensing
0 to +3,000 m (0 to + 10,000 ft)
0 to +15,000 m (0 to +50,000 ft)
IEC 801-2 level IV, 801-4 level IV, 801 -5 level III
<45 dBA
22.2 x 22.8 x 21.6 cm
(8.65 x 9.0 x 8.5 in)
10.2 (11.2) Kg
22.4 (24.7) Lb
7.5 (8.4) Kg
16.4 (18.6) Lb
Listed to UL 1778 Compliance to CSA 22.2
Normal and common mode EMI/RFI suppression
one 12v, 7 Ah
one 12v, 11 Ah
surge protection
let-through (as a percentage of an
a/-6 kV 1.2/50 us, 500
a 8/20 us test)
Telephone line surge protection let-through
(as a percentage of an a/-6 kV 1.2/
50 us, 500 a 8/20 us test
6.9 (8) Kg
15.4 (17.6) Lb
Safety and approvals
EMC Verification
FCC Class B certified
Acceptable input voltage
Input voltage (on-line operation)
Output voltage
Nominal input frequency
Input protection
Frequency limits (on-line operation)
Transfer time
Maximum load
On-battery output voltage
On-battery frequency
On-battery waveshape
Protection
Surge energy rating
(one time, 10/1000 us waveform)
Surge current capability
(one time, 8/20 us waveform)
Surge response time
Surge voltage let-through
(percentage of applied ANSI
C62.41 Cat. A +/-6 V test waveform)
Noise filter
Battery Type-Spill proof, maintenance
free, user replaceable, sealed lead-acid
Typical battery life
Typical recharge time
Operating temperature
Storage temperature (see Section 11)
Operating and storage relative humidity
Operating elevation
Storage elevation
Electromagnetic immunity
Audible noise at 1 m (3 ft.)
Size (H x W x D)
Weight - Net (Shipping)
MBK Series
Date of manufacture
1826
Enabled
Enabled
t
105 VAC (200 for 230
VAC models)
Use this function to uniquely
identify the UPS in your net-
work configuration
Enter the current date when
replacing batteries
When enabled, the UPS will
automatically restart from a
low battery shutdown when
normal A/C returns
Enabled - the UPS will emit
a short beep when in the
battery mode. At Low Bat-
tery the UPS will emit two
tonesfrom low battery warn-
ing until shutdown.
Disabled - Use only when
software is controlling the
UPS or to silence the alarm
Changes the voltage point at
which the UPS switches to
battery power
(These items require optional software or hardware)
FUNCTION
FACTORY DEFAULT
DESCRIPTION
Up to 64 characters to
define the UPS
Date of battery re-
placement -
day/month/year
XX/XX/XXXX
Up to 5 characters
Enable or disable
Enabled, at low bat-
tery, disabled
98 or 91 VAC (185 or
170 VAC for 230 VAC
models)
USER CHOICES
UPS ID
Battery install
date
Battery life in
days
Enable/
Disable auto
resstart
Set audible
alarm state
Set low voltage
Xfer point
9
At first battery replacement,
reset to reflect actual num-
ber of days experience in
your environment or leave
factory default.
CON
FIGURABLE PARAMETERS
& SETTINGS
10
LIMITED PRODUCT WARRANTY
Para Systems Inc. (Para Systems) warrants this equipment, when properly applied and
operated within specified conditions, against faulty materials or workmanship for a period of
three years from the date of manufacture. For equipment sites within the United States and
Canada, this warranty covers repair or replacement of defective equipment at the discretion
of Para Systems. Repair will be from the nearest authorized service center. Replacement
parts and warranty labor will be borne by Para Systems. For equipment located outside of
the United States and Canada, Para Systems only covers faulty parts. Para Systems
products repaired or replaced pursuant to this warranty shall be warranted for the unexpired
portion of the warranty applying to the original product. This warranty applies only to the
original purchaser who must have properly registered the product within 10 days of purchase.
The warranty shall be void if (a) the equipment is damaged by the customer, is
improperly used, is subjected to an adverse operating environment, or is operated outside the
limits of its electrical specifications; (b) the equipment is repaired or modified by anyone other
than Para Systems or Para Systems-approved personnel; or (c) has been used in a manner
contrary to the products operating manual or other written instructions.
Any technical advice furnished before or after delivery in regard to use or application of
Para Systemss equipment is furnished without charge and on the basis that it represents
Para Systemss best judgment under the circumstances, but it is used at the recipients sole
risk.
EXCEPT AS PROVIDED HEREIN, PARA SYSTEMS MAKES NO WARRANTIES,
EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit limitation of implied
warranties; therefore, the aforesaid limitation(s) may not apply to the purchaser.
EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL PARA SYSTEMS BE LIABLE
FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES
ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBIL-
ITY OF SUCH DAMAGE. Specifically, Para Systems is not liable for any costs, such as lost
profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data,
cost of substitutes, claims by third parties, or otherwise. The sole and exclusive remedy for
breach of any warranty, expressed or implied, concerning Para Systemss products and the
only obligation of Para Systems hereunder, shall be the repair or replacement of defective
equipment, components, or parts; or, at Para Systemss option, refund of the purchase price
or substitution with an equivalent replacement product. This warranty gives you specific legal
rights and you may also have other rights which vary from state to state.
Longer term and F.O.B. job site warranties are available at extra cost. Contact Para
Systems (1-972-446-7363) for details.
LIMI
TED PRODUCT WARRANTY
www.minuteman-ups.com
1455 LeMay Dr.
Carrollton, Texas 75007
Phone: (972) 446-7363
Fax (972) 446-9011
PN: 34000123 rev 1
NOTE: 230VAC Specs Shown In ( ) 300 VA 320VA 520VA 680VA
300VA
195W
one 12v, 4.5 Ah
17.1 x 17.1 x 16.5 cm
(6.75 x 6.75 x 6.5 in)
4.7 (5.2) Kg
10.1 (11.4) Lb
DECLARATION OF CONFORMITY
Application of Council Directive(s):
89/336/EEC, 7/23/EEC
Standard(s) to which Conformity is declared:
EN50091-2, EN60555-2, EN61000-3,
EN50091-1
Manufacturers Name:
Para Systems, Inc. (Minuteman Power Supplies)
Manufacturers Address:
1455 LeMay Drive
Carrollton, Texas 75007 USA
Type of Equipment: Uninterruptible Power Supplies
Model No:
MBK 300YYY, MBK 320YYY, MBK 520YYY, MBK 680YYY
,
Year of Manufacture: Beginning September 1, 1998
I, the undersigned, hereby declare that the equipment specified above
conforms to the above Directive(s).
Place: Carrollton, Tx USA
Shawn Delavar
(Signature)
Date: September 1, 1998
Shawn Delavar
(Full Name)
Regulatory Compliance Engineer
(Position)