Maintenance/Service
7.6
Dismount Plate Filter
Proceed as follows for dismounting of
the plate filter:
- Open seat hood.
- Remove cover.
- Loosen fillister head screws
(Fig. 16/2) and remove.
- Fold back frame with electro-motor
(Fig. 16/3).
- Hook frame at indicated position
(Fig. 16/4).
- Remove plate filter (Fig. 16/5).
For mounting of plate filter proceed in
inverse order.
Fig. 16
Plate filter
1. Detent hook
2. Fillister head screws
3. Frame with electro-motor
4. Opening holding the detent hook
5. Plate filter
1
2
2
3
4
5