Page 31
Ambassador 20 988403 Rev G 04/22
Electrical System A.C.
Solution Recovery (cont’d)
II. Pump motor does not run.
A. Check pressure switch for short circuit. By-pass the pressure switch by connecting
the two black leads to the switch to one another, if the motor then runs, replace the
pressure switch.
III. Machine fails to run when handle switch is activated.
A. Speed control maybe shorted out.
B. Speed control potentiometer may be defective.
I. Vacuum motor does not start.
A. Inspect the micro switch lever inside the electrical enclosure to make sure it is
functioning properly. As the scrub head is lowered the lever should activate
the switch. Bend the switch lever to adjust function if required.
B. Check motor carbon brush.
C. Check plugs on power cord.
FOR ALL THE ABOVE MAKE SURE ALL THE ELECTRICAL CONNECTIONS ARE SECURE. MAKE SURE THE CORD
TO THE WALL OUTLET IS SECURE. MAKE SURE THE GFCI IS NOT TRIPPED IF THE UNIT IS EQUIPPED WITH ONE
(LOCATED ON POWER CORD).
Summary of Contents for Ambassador 20
Page 5: ...Page 5 Ambassador 20 988403 Rev G 04 22...
Page 12: ...Page 12 Ambassador 20 988403 Rev G 04 22 Tank Assembly I Exploded Views...
Page 15: ...Page 15 Ambassador 20 988403 Rev G 04 22 Tank Assembly II...
Page 18: ...Page 18 Ambassador 20 988403 Rev G 04 22 Base Assembly...
Page 19: ...Page 19 Ambassador 20 988403 Rev G 04 22...
Page 20: ...Page 20 Ambassador 20 988403 Rev G 04 22 7...
Page 21: ...Page 21 Ambassador 20 988403 Rev G 04 22 635 1 77 0 17 6 7...
Page 22: ...Page 22 Ambassador 20 988403 Rev G 04 22...
Page 23: ...Page 23 Ambassador 20 988403 Rev G 04 22...
Page 27: ...Page 27 Ambassador 20 988403 Rev G 04 22 Rev C THIS PAGE INTENTIONALLY LEFT BLANK...
Page 32: ...Page 32 Wiring Diagram...
Page 33: ...Page 33...