Minuteman 957740 Manual Download Page 6

www.minutemanintl.com

6

31218C

WIRING DIAGRAM

PARTS LIST FOR 36 VOLT

AUTOMATIC BATTERY CHARGER

PART NO. 957740

120 VAC / 60 HZ

PART NO.            QTY.                DESCRIPTION                                                                                

31236S

1

CASE ASSEMBLY

17095S

1

TRANSFORMER ASSEMBLY

02390S

1

CAPACITOR, 6 MFD, 660 VAC

16946S

2

HEATSINK ASSEMBLY W/ 2 DIODES IN PARALLEL

08774S

1

FUSE ASSEMBLY

16823S

1

AMMETER, 50 AMP, W/ CORNER MOUNTING STUDS

24840S

1

TIMER KIT, 36 VDC, 120 VAC

* 04484S

1

RELAY, FOR ELECTRONIC TIMER

** 23385S

1

RELAY, FOR ELECTRONIC TIMER

04484S

1

TIMER KIT RELAY, 36 VDC, SPSTNO, 120 VAC

02028S

1

CORDSET BUSHING, 7W-2, FOR 14/3 INPUT CORDSET

02008S

1

CORDSET BUSHING, 8P-2, FOR 10/2 OUTPUT CORDSET

02506S

1

AC CORDSET, 14/3, 72" W/ 125V/15A PLUG

08329S

1

DC CORDSET, 10/2, 108", W/ SB175 GRAY PLUG

*  FOR USE WITH CHARGERS BUILT BEFORE 04/04

**  FOR USE WITH CHARGERS BUILT AFTER 04/04

Summary of Contents for 957740

Page 1: ...inish rate with constant electrolyte temperature No taps or rate controls to set Automatic decrease of charge rate for superior battery life through good equalization of cells and low water use rate Silicon diodes with inherent surge protection operated at a conservation percentage of their rating Convection cooled design for maximum reliability and minimum maintenance INTRODUCTION This automatic ...

Page 2: ...CAN RESULT IN A RISK OF ELECTRIC SHOCK The conductor with insulation having an outer surface that is green with or without yellow stripe s is the equipment grounding conductor If repair or replacement of the electric cord or plug is necessary do not connect the equipment grounding connector to a live terminal Refer to a qualified service agent Battery chargers equipped with a grounding plug as ill...

Page 3: ...te will decrease to 6 to 10 amperes for the last few hours of charge if all battery cells test good During charge the battery voltage increases gradually causing the charge rate to decrease Good battery cells should each rise to approximately 2 5 volts DC causing the charge rate to reduce to less than 10 amps Each cell accepts charge differently normal charging with the ammeter reading in the 6 to...

Page 4: ... to know how long the batteries have been stored 3 Limit the use of new batteries for the first 20 cycles New batteries and older batteries that have been in storage are not capable of their rated output until they have been discharged and charged a number of times 4 Do not excessively discharge the batteries Excessive discharge can cause polarity reversal of individual cells resulting in complete...

Page 5: ... the event one or both rectifier diodes fail or a reverse polarity connection is made to the batteries Check the fuse assembly visually for an open or blown fuse link If both half links of the fuse assembly blow as soon as the DC output plug is connected to the battery connector the polarity of the batteries may be reversed If no battery or connector maintenance has been performed prior to the fus...

Page 6: ... FUSE ASSEMBLY 16823S 1 AMMETER 50 AMP W CORNER MOUNTING STUDS 24840S 1 TIMER KIT 36 VDC 120 VAC 04484S 1 RELAY FOR ELECTRONIC TIMER 23385S 1 RELAY FOR ELECTRONIC TIMER 04484S 1 TIMER KIT RELAY 36 VDC SPSTNO 120 VAC 02028S 1 CORDSET BUSHING 7W 2 FOR 14 3 INPUT CORDSET 02008S 1 CORDSET BUSHING 8P 2 FOR 10 2 OUTPUT CORDSET 02506S 1 AC CORDSET 14 3 72 W 125V 15A PLUG 08329S 1 DC CORDSET 10 2 108 W SB...

Page 7: ...ctory to the owner will be paid for by the owner All warranty work accomplished at the Minuteman factory will be completed with a reasonable time after receipt of defective items This warranty does not cover any semiconductor parts such as diodes which are vulnerable to electrical overloads beyond the control of Minuteman This warranty does not cover any charger that has been subject to misuse neg...

Reviews: