Minuteman 1000 VA Specification Download Page 4

MINUTEMAN

®

 CPE

 Series Specifications

© Copyright 2006, Para Systems, Inc.  Product specifications are subject to change without notice. MINUTEMAN is a registered trademark and MINUTEMAN CPE is a trademark of Para Systems, 

Inc.  

MINUTEMAN UPS / Para Systems, Inc.
1455 LeMay Drive, Carrollton, TX 75007

Phone 800.238.7272  +1 972.446.7363  Fax +1 972.446.9011

PN-34000289 - 10-09

Model

 

 

 

 

    

    1000 VA 

                              2000 VA 

              3000 VA

Input 

 

 

 

 

 

   

 

Voltage (VAC)   

 

 

 

80 - 140

Frequency 

 

 

 

 

50/60 +/- 5% (Auto Sensing)

Phase 

 

 

 

 

Single 

   

 

Input Power Factor Correction   

 

>0.98 (Full Load)

Input Power Cord (NEMA) 

 

      5-15P 

5-20P 

     L5-30P

Output 

Voltage (VAC)   

 

 

 

100/110/115/120

Capacity (VA/W)   

 

 

1000VA/700W 

2000VA/1400W 

3000VA/2100W

Rated Power Factor 

 

 

 

0.7 Lagging

Load Power Factor Range 

 

 

0.5 Lagging to Unity within KW Rating of Unit

Wave Form 

 

 

 

 

Sine Wave, THD <3% (no load to full load)

Voltage Regulation 

 

 

 

+/- 2%

Transient Response (ms) 

 

 

+/- 4% Under Full Load, Change and Corrected within 60 ms 

Frequency Stability 

 

 

 

+/- 0.5 Hz (Free Running)

Synchronization   

 

 

 

Slew Rate: 1 Hz/Sec. Max  Synchronizing /-5%

Transfer Time   

 

 

 

0 ms

Crest Factor 

 

 

 

 

3:1

Runtime (Full Load) 

 

               

>8 min.          

 >7 min.         

  >8 min. 

DC Start 

 

 

 

 

Yes

Outlets (NEMA) 120 VAC 

 

4 x 5 - 15R   

4 x 5 - 15R + 2 x 5 - 15/20R 

6 x 5 - 15R + 2 x 5 - 15/20R

Display

LED Indicators   

 

           Utility, Battery Low, Inverter, Bypass, Test OK, Overload Fault, Load/Battery Level, and System Fault Conditions

Self Diagnostics   

 

 

 

On-Demand Push Button

Alarms

Audible and Visual 

 

 

 

Line Failure, Battery Low, Transfer to Bypass, Overload, System Fault Conditions

Physical

Tower Net Dimensions (WxHxD, in.) 

5.8 x 8.78 x 15.8 

5.1 x 14.4 x 18.9 

7.5 x 14.4 x 17.8

Tower Net Weight (lbs. / kg) 

 

      33 / 15   

60 / 27 

      79 / 36

Environmental

Operating Temperature   

 

 

 

0

°

 C - 40

°

 C

Altitude 

 

 

 

 

 

0 to +10,000 ft

Humidity 

 

 

 

 

 

30 to 90% RH Maximum, Non-condensing

Noise 

 

 

 

 

 

< 45 dB at 1 meter

Safety Conformance   

 

 

 

Safety Standard   

 

 

 

 

EN500091-1, UL1778, CSA 22.2

EMC Standard   

 

 

 

EN500091-2, EN61000-3-2, EN61000-3-3, FCC Class A 

Agency Marks   

 

 

 

 

UL, CE, cUL

Tower Models (Rear View)