135
3-2.
Power supply malfunctions
(1)
No power
<Remedy>
Electrical components for detection of the malfunction
Power unit (PU)
Power switch (S1)
Master board (PWB-A)
Step
Remedy
Reference
page
WARNING DIAGRAM
Control signal
Location(electrical com-
ponent)
1
Check if the power supply cord
is connected to the main unit.
-
-
-
2
Check S1 operation.
-
-
2-A
3
Replace the power unit.
-
-
-
4
Replace PWB-A.
-
-
-