![Minolta Di181 Service Manual Download Page 36](http://html.mh-extra.com/html/minolta/di181/di181_service-manual_1803048036.webp)
FrameMaker Ver.5.5E(PC) Di181 GENERAL, MECHANICAL/ELECTRICAL
99.07.16
M-32
÷
The speed at which the Scanner is moved is controlled by varying the period of the motor
drive pulse that is timed with the reference clock.
÷
The distance over which the Scanner travels is controlled by the number of motor drive
pulses that correspond to each paper size and zoom ratio.
14-5. Scanner Motor Drive Control
CONTROL SIGNAL
ON
OFF
WIRING DIAGRAM
M5
PWB-F PJ3F-1~4
Pulse Output
15-B
Period
High Speed
Low Speed
1177M059CB