4.
SET
SCREWS
OUTLET BOX
HANGER BRACKET
REMEMBER to turn off the power.
Follow the steps below to hang
your fan properly:
Step 1. Secure the hanger bracket
to the ceiling outlet box using
screws, lock washers, and flat
washers included with the fan.
(Fig. 5)
Step 2. Loosen the two set screws
in the top coupling of the motor
assembly. (Fig. 6)
Step 3. Remove downrod hanger
ball by loosening set screw,
removing the cross pin, and
sliding ball off rod. Remove the
hitch pin and lock pin. (Fig. 7)
Step 4. Carefully feed fan wires up
through the downrod. (Fig. 8)
Thread the rod into the coupling,
next line up holes, then replace
lock pin and hitch pin. Tighten set
screws.
Step 5. Slip canopy onto downrod.
(Fig. 9). Carefully reinstall hanger
ball onto rod being sure that
crosspin is in correct position, set
screw is tight and wires are not
twisted.
Step 6. Now lift motor assembly
into position and place downrod
ball into hanger bracket. Rotate
until the check groove has dropped
into the registration slot and seats
firmly. (Fig. 10). Rod should not
rotate if this is done correctly.
DOWNROD
HITCH
PIN
SET
SCREW
LOCK
PIN
SUPPLY
WIRES
FIG. 5
FIG. 6
FIG. 7
FIG. 8
FIG. 9
FIG. 10
HANGER BALL
CANOPY
HITCH PIN
SET
SCREW
FAN HOUSING
LOCK PIN