16
3.2.3.3
12V Trigger
The PWR-16 can be turned on with an external 12V trigger signal. This is applied to Pin 3, with Pin 5 used as
ground reference. The amplifier will be turned on when the trigger signal is at 12V and off when it is at 0 V. Pin 4
is hard-wired to Pin 3, and is intended for use as a 12V trigger output.
To use an external 12V trigger:
Set the 3−5V Trigger switch to
Off
.
Set the External Signal Sense switch to
Off
.
Leave
Pin 6, 3−5V Trigger IN
disconnected.
Connect the trigger signal to
Pin 3, 12V Trigger IN
, using
Pin 5, Logic/Trigger ground
as ground reference.