8.

 

Troubleshooting Guide 

Please refer to this troubleshooting guide for the possible cause and solution to your problem. If you cannot resolve 
on your own, see “Minibar Systems Contact Information” at the end of this manual. 

The SmartFridge fails to operate after connecting to electrical power supply:  

 

Check the power cord is properly connected.  

 

Check the power supply in the electrical outlet (blown fuse / circuit breaker).  

 

Make sure the SmartFridge is working.  

Continuous operation of the cooling system:  

 

The door is frequently opened or left open for too long.  

 

The door is not properly closed (the door may sag; the gasket may be polluted or damaged).  

 

Perhaps you may have overloaded the SmartFridge with fresh food.  

 

The reason may be inadequate ventilation of the compressor (assure adequate air circulation).  

Ice formation on the inner rear wall:

 

As long as the defrost water runs to the channel and through the outlet to the drain pan on the compressor, 
automatic defrosting of the SmartFridge is assured. In case ice formation on the inner back wall is increased 0.12” (3 
mm) - 0.20” (5 mm) ice should be manually defrosted.  

 

Disconnect the SmartFridge from the power supply and leave the door open. Never use electric devices for 
defrosting and do not scrape the ice of frost layer with sharp objects.  

 

After defrosting is complete close the SmartFridge door and reconnect to power supply. The cause of increased 
ice formation may be one of the following:  

 

the door does not seal well (clean the gasket if it is contaminated or replace if damaged)  

 

the door is frequently opened or left open for too long  

 

the food stored in the refrigerator was warm  

 

the food or dish is touching the inner back wall.  

Water is leaking from the SmartFridge: 

If the discharge water outlet is clogged, or the defrost water drips  over the channel, water  will leak from the 
SmartFridge.  

 

Clean the clogged outlet, for example with a plastic straw or pipe cleaner.  

 

Manually defrost the increased ice layer (see 

“Ice formation on the inner rear wall”)

.  

 

Noise:  

A compressor-based refrigerator does produce a certain level of noise. How noisy the SmartFridge  is depends on 
where it is placed, how it is used and how old the SmartFridge is. During the operation of the compressor the noise 
of the liquid is heard. This is a normal condition and does not relate to the lifetime of the SmartFridge. After starting 
the SmartFridge the operation of the compressor and the refrigerant flow may be louder - this does not mean that 
something is wrong and does not relate to the lifetime of the SmartFridge. Occasionally unusual and louder noise 
can be heard. This noise is often a consequence of incorrect installation, check that:  

 

the SmartFridge is level and installed on a firm solid base / floor;  

 

it does not touch the case good cabinet;  

 

the accessories on the interior have been placed correctly in their positions; and check, bottles, tins and other 
vessels are not touching each other causing rattling and/or vibrations.  

 

Summary of Contents for SmartFridge 50

Page 1: ...martFridge 50 Full Glass Door User s Guide 100 127V 60Hz 50 G AC ET 220V 240V 50 60Hz 50 G AC ET SmartFridge 50 Full Glass Door User s Guide_Rev 5 doc Page 1 SmartFridge 50 Full Glass Door User s Guid...

Page 2: ...Ventilation Basic Principles 4 3 Grounding Instructions 4 4 Installation 4 4 1 Before Putting in Use 4 5 Use of the LED Control Panel 5 5 1 Display 5 5 2 Buttons 5 5 3 Modes 5 5 4 Special Features 6...

Page 3: ...cooled with a cooling plate mounted on or in the rear wall Under the plate there is a channel and a drain water outlet for defrosting water Regularly check the defrost water outlet and the drain chann...

Page 4: ...t will be trapped The SmartFridge must not be placed against a heating radiator window curtains or in direct sunlight Ventilation grills or slots must not be covered 3 Grounding Instructions The mains...

Page 5: ...nce reached the SmartFridge will operate in ON mode F C Pressing the F C button will toggle the temperature display between degrees Fahrenheit or Celsius 5 3 Modes DOOR Opening or closing the door wil...

Page 6: ...e will switch the SmartFridge to ON mode The display will turn off after 10 seconds of non use A GONG Go No Go test is executed at power up All the LEDs flash and all the segments rotate on the displa...

Page 7: ...Remove the four screws 3 from the bottom hinge 4 Gently take the door off from the top hinge 2 See Diagram 1 Unscrew the top hinge 2 and fix it onto the opposite side Remove two screws 1 on the door...

Page 8: ...tools recommended by the manufacturer The refrigerating system of the SmartFridge is filled with refrigerant and oil so when the SmartFridge is damaged handle it with care and dispose of it in complia...

Page 9: ...fter defrosting is complete close the SmartFridge door and reconnect to power supply The cause of increased ice formation may be one of the following the door does not seal well clean the gasket if it...

Page 10: ...warm foods make sure that they are cooled to ambient temperature If the gasket is damaged or the door seal is poor energy consumption is substantially higher Replace damaged door gaskets as soon as po...

Page 11: ...and serial numbers You ll find them on a plate located on the rear outside wall of the Fridge Please write these numbers here ____________________________________ Date of Purchase ____________________...

Reviews: