background image

 

User Manual

 

 

 

 
 
2021 

 

Page 15 

 

 

 

 Temperature Regulation: 

 

•  The operating temperature of the SmartCube  is subject to many factors: the correct and level 

installation, proper ventilation, the internal product load

,

 etc. 

•  The temperature control box is factory set for optimum performance for the SmartCube. 
•  For cooling adjustment, the temperature control box can be reset by moving the dial on the unit – see 

the Temperature Adjustment Diagram below. 

•  The box is positioned on the back of the SmartCube.  
•  The cooling cycle has automatic defrost every 24 hours. 

 

 

Temperature Adjustment Diagram 

 

The factory setting can be adjusted by rotating the dial. 

 

MAX is for maximum cooling. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Enabling and Disabling Optional Lighting 

 

SmartCube has a standard exterior and interior lighting feature for Flexi and Automated models. The 

intensity of the lighting is controlled via the S3 software and can be adjusted from an off position to level 

10 as desired. This is a programmable feature set up during the installation of the SmartCubes at the 

hotel. Classic model lights are not programmable. If the hotel requires the BLUE LEDs to be switched off, 

there is an isolator switch fitted to the PCB at the front of the service tray. It can be set to the off 

position.Enabling and Disabling Optional Lighting: 

 

 

MIN  37.4

°

F/ 3

°

 1  42.8

°

F/ 6

°

 2  48.2

°

F/ 9

°

MED  53.6

°

F/ 12

°

 3 

59

°

F/ 15

°

 4  64.4

°

F/ 18

°

MAX  71.6

°

F/ 22

°

 

Summary of Contents for SMARTCUBE DualBar

Page 1: ...User Manual Revised on 05 09 2022 Page 1 MINIBAR SYSTEMS USER MANUAL Installation Instructions Operating Instructions and Case Good Specifications Models SC 40T and DualBar...

Page 2: ...al Electronic Lock 14 6 Temperature Regulation 15 7 Enabling and Disabling Optional Lighting 15 8 Communications 16 9 Routine Maintenance and Cleaning 16 10 Installation Instructions 17 10 1 Door Shel...

Page 3: ...or explosion This appliance is intended to be used in household and similar applications such as o staff kitchen areas in shops offices and other working environments o farm houses and by clients in...

Page 4: ...ly to the SmartCube must be clean and stable Make sure the mains power cord or any other cables are not trapped under the unit If the mains power cord is damaged at any time it must be replaced by Min...

Page 5: ...proper ventilation for the SmartCube is imperative to ensure maximum efficient operation of the cooling unit The SmartCube must not be placed against a heating radiator window direct sunlight or curta...

Page 6: ...d to prevent the case good from being pushed against the wall The underside of the shelf above the SmartCube must be flat so no obstruction is caused to the airflow In this instance the back of the un...

Page 7: ...7 475 mm DualBar 22 92 582 4 mm 28 465 723 mm 18 7 475 mm Insertable Cavity Opening see Diagram A in Section 4 Height Width Depth SC 40 26 66 677 mm 20 47 520 mm 23 43 595 mm GF 27 26 66 677 mm 16 532...

Page 8: ...59 mm 13 330 2 mm 3 65 92 71 mm 8 sensors 85 21 59 mm 13 330 2 mm 6 3 160 02 mm 10 sensors 85 21 59 mm 16 1 409 mm 6 3 160 02 mm SmartTrays come in the following leatherette Short configurations Smar...

Page 9: ...onfigurations SmartTray Height Width Depth 4 sensor Leatherette 3 125 79 38 mm 14 8 375 92 mm 4 8125 122 2375 mm 8 sensor Leatherette 3 125 79 38 mm 14 8 375 92 mm 8 0625 204 787 mm 10 sensor Leathere...

Page 10: ...114 3 mm 4 5 114 3 mm Two single sensors 2 5 63 5 mm 9 228 6 mm 4 5 114 3 mm 4 sensor Flat Tray 2 5 63 5 mm 16 125 409 57 mm 6 75 171 45 mm 8 sensor Flat Tray 1 875 47 63 mm 16 5 419 1 mm 9 625 244 48...

Page 11: ...ivider wall in the case good if an optional electronic lock and or ambient snack trays are installed The diagram illustrates drilling for both right hand and left hand hinged bars If the ambient snack...

Page 12: ...All dimensions are internal Placement of bar begins 0 5 13 mm inside the case good door All tolerances 0 12 3 mm If the key is stored in the minibar lock allow an additional 1 2 30 mm 8 203 2 mm reco...

Page 13: ...e For safety secure or anchor the SmartCube to the floor using screws appropriate for the material and thickness of the case good floor Holes can be found in each front foot and covers are provided fo...

Page 14: ...sistance See Section 3 3 if using multiple trays hole placement may vary All dimensions are internal All tolerances 0 12 3 mm Roller catches are not required if optional electronic lock is used Not to...

Page 15: ...etting can be adjusted by rotating the dial MAX is for maximum cooling Enabling and Disabling Optional Lighting SmartCube has a standard exterior and interior lighting feature for Flexi and Automated...

Page 16: ...and Cleaning If the unit is fitted with an absorption cooling unit it is recommended on an annual basis to check for any leakage or small yellow type stains If present change the cooling unit Please c...

Page 17: ...Door Shelf Replacement To remove the door mounted shelf you will need to first remove the rubber plug on the left side of the door shelf column that is protecting the un used backplane connector Free...

Page 18: ...ual 2021 Page 18 The door rack will now be loose and able to slide out the upper and lower door rack kit Un screw the right side door shelf column using a Philips head screw driver and remove the shel...

Page 19: ...User Manual 2021 Page 19 Disconnect door sensor shelf from the backplane board and the release engagement feature by sliding door sensor shelf to the right Remove the sensor shelves for replacement...

Page 20: ...shelf MB MA 0035 into the bottom support and connect it to the backpane Screw the right side door shelf column using a Philips head screw driver to secure the sensor shelves Slide the rack kit between...

Page 21: ...User Manual 2021 Page 21 Install the rubber plug back to cover the un used backplane connector...

Page 22: ...the lock bar that is located on the right side inner wall of the SmartCube minibar To unlock the sensor shelves from the backplane frame lift up on the locking bar Slide out the sensor shelves carefu...

Page 23: ...ividers MB PP 0005 and PULF0015 to the sensor shelves Once assembled onto sensor shelf MB MA 0034 slide the sensor shelves in the slots of the cube to connect onto the backplane connectors Push down o...

Page 24: ...Page 24 Console Box Replacement Switch off the Console Box power supply unit and then disconnect all cables from it Un Screw the Console Box from the back of the SmartCube by removing three Philips he...

Page 25: ...nstallation Mount the Console Box to the SmartCube back using 2 Round Philips Head screws MB NP 0027 and 1 Flat Philips Head screw MB NP 0029 Connect all cables back according to the wiring diagram an...

Page 26: ...ide Enabled when electronics malfunctions Open the lock cover by removing the Philips Head screw using a screw driver Press the override pusher head down and rotate by 90 degrees in a clockwise direct...

Page 27: ...ronics functions Press the override head down and rotate it by 90 derees in the counter clockwise direction to release the locking bar to resume E lock function Screw the anti tamper cover back ono th...

Page 28: ...nsional drawing for proper ventilation Reference to the dimensional drawings Fix the rear anchor bracket onto the case good using the gauge template or refer to the dimensional drawing for mounting lo...

Page 29: ...ord is connected to the SmartCube and then push the SmartCube SC 40T into the cabinet against the rear anchor bracket Connect the other end of the IEC power cord MB CA 0016 to the SmartCube GuestFridg...

Page 30: ...s to case good open doors and the bracket is located on the bottom lip of the cold cube Screws MB NP 0026 packed in accessory back along with the bracket Casegood ventilation is emparative to unit fun...

Page 31: ...ensional drawing for proper ventilation Reference to the dimensional drawings Fix the rear anchor bracket onto the case good using the gauge template or refer to the dimensional drawing for mounting l...

Page 32: ...ase good Open the door to screw the bottom of the SmartCube to the case good Screws MB NP 0026 packed in accessory back along with the bracket Casegood ventilation is emparative to unit function and o...

Page 33: ...nformation contact your Minibar Systems representative The majority of all plastic parts are marked with an internationally standardized abbreviation for graded recycling This will enable plastic wast...

Page 34: ...ne FR 92508 Rueil Malmaison Cedex tel 33 1 55 47 07 07 fax 33 1 47 49 61 62 minibar france minibar ch www minibar ch Germany Minibar Germany GmbH Co Venloer Strasse 151 153 D 50672 K ln tel 49 2271 99...

Reviews: