Junction box / sensor diagnosis

 

 
 

Built into the software of the Intea junction box there is a diagnostic mode. This mode 
can detect if there is a sensor fault or internal component fault in the junction box.  

 

With setting 

3 on the junction box

, the test procedure is as follows. 

 

A)  

Sensor  

 

If the sensor is faulty the JB will supply power to the heater in the following 
sequence: 60 seconds ON / 12 seconds OFF 

 

B) Junction 

Box 

 

If there is a failure of component within the JB the power supply to the heater is 
in the following sequence:  80 seconds ON / 16 seconds OFF 

 

Test method 

 

The above tests require that power is applied to the JB.  The suggested procedure is 
as follows: 

 

1.

 

Remove the power cable from the JB 

2.

 

De-mount the JB from the rear of the Minibar 

3.

 

Disconnect the wires to the heater/resistance 

4.

 

Connect a test lamp 60W bulb and lead with Faston connectors to the heater 
terminals on the JB.  Check bulb voltage corresponds to JB voltage.  Re-fix the 
JB to the Minibar. 

5.

 

Connect the power lead 

6.

 

Turn on power and check the lamp function to identify a condition as per A) or 
B) above. 

7.

 

If a volt meter is available, the voltage across the terminals of the lamp can also 
be measured to check function.  To facilitate this a block connector should be 
installed in the cable between the lamp holder and the Faston connectors. 

 
 

Summary of Contents for Primo 30

Page 1: ...ses AG Blegistrasse 9 CH 6340 Baar tel 41 41 767 23 00 tax 41 41 767 23 23 info minibar ch www minibar ch Minibar North America Inc 7340 Westmore Road Rockville MD 20850 tel 1 301 309 1100 fax 1 301 3...

Page 2: ...heater element 7 5 To change INTEA junction box 8 6 To change a sensor 9 7 Junction box sensor diagnosis 11 8 To change door hinge from right to left 12 9 To mount door frames and laminate panel 13 1...

Page 3: ...part of the system called the condenser where with the help Illustration 1 Absorption cooling unit of the cooling fins it causes the temperature to drop thus condensing only the ammonia from gas to a...

Page 4: ...ing to handbook If cold a Check heater resistance b Thermostat function c Timer not on defrost cycle Bar is level Bar warm at rear but not cooling inside Overheating at rear of bar Ventilation correct...

Page 5: ...ove 3 screws securing junction box 4 Cut cable tie securing insulation sleeve to base of silent cooler 5 Carefully remove junction box from rear of minibar Fixing screws Heather sleeve cable tie Heate...

Page 6: ...water drain reservoir at rear base of chiller 9 Remove screw securing lower section of chiller 10 Remove silver paper from rear of evaporator tube to expose styrene insulation 11 Hold the end of cond...

Page 7: ...e connect heater wires 2 Faston to junction box terminals 19 Re fix junction box take care with position of cables 20 Secure insulation sleeve to lower part of chiller with cable tie 21 Re connect pow...

Page 8: ...ulation sleeve for cables from old unit if not supplied with new 4 Locate heater to location ring on boiler tube ensure area is clean before replacing 5 Re position jubilee clip and re tighten correct...

Page 9: ...ear of the minibar cabinet TAKE CARE Ensure that the cables run through the holes slots to prevent trapping of cables 4 Re connect power lead and check control is on position 3 as defined in the instr...

Page 10: ...e from the interior the socket with cable will pass the hole with care 6 In some cases it is necessary to remove the evaporator plate 4 screws to allow free passage of the cable To replace 7 Feed the...

Page 11: ...6 seconds OFF Test method The above tests require that power is applied to the JB The suggested procedure is as follows 1 Remove the power cable from the JB 2 De mount the JB from the rear of the Mini...

Page 12: ...hand hinge hole 6 With a sharp point push out the hinge blanking plate and insert into the right hand hinge hole 7 Re fix with the 2 screws 8 Remove the bottom hinge pin and washers from the right ha...

Page 13: ...nsure that on the top corners the laminate is well under the frames 5 Fit the frames firstly the top then each side Ensure that the side frame is well inside the top if not push from the bottom 6 Secu...

Page 14: ...event lower hinge from binding 2 As a further precaution it has been found that 2 other factors can be adjusted i Remove the bottom hinge and insert extra washer s on the lower hinge pin Some early pr...

Page 15: ...VOLTAGE 6 Push the lamp cover back in place 13 To change a power cable The Primo minibar has a de mountable power cable using a similar IEC connector as used in most computers It is possible to chang...

Reviews: