![minibaby MINIS80 Instruction Manual Download Page 8](http://html1.mh-extra.com/html/minibaby/minis80/minis80_instruction-manual_1801929008.webp)
Automatic power-off function
:
After 10 minutes of startup, the program does not start, the power supply is automatically cut off,
the washing program is finished, and the power supply is automatically cut off by the washing machine.
Automatically alarm for 1 hour without handling, automatically cut off the power supply
Troubleshooting
Troubleshooting
Enter water
failure
Have not open the tap , stop water ,
low water pressure , water have
not reach the set water level after
20 minutes
Open the tap . Clean the netting according
to the method of “Cleaning the water inlet “
Drain failure
The drain hose is placed too high
or have not lay down the drian hose .
The drain hose is wrung or jammed
Check the drain hose , lay the drain hose
lowly . Press “Start/Pause ”button after
checking .Open the machine cover and
close the machine cover for alarm free
Open abnormal Safety lid is open
Closed the lid
Water level up
on the highest
safety water level
PCB can Auto-precess
Sensor of water
lever abnormal
Please ask professional person to check
Stage frequency less than high
water level limit or exceed than
low water level limit , will shows
sensor of water lever error alarm
Pause abnormal Pause time exceed 10 minutes
Please press the “Start” button
Temperature
sensor abnormality Short Circuit of Temperature Sensor
Return to normal or switch to normal
temperature water automatically
water temperature
above the maximum
water temperature set
Water temperature above 93 degrees
To be cooled by water temperature or
automatically switch to high temperature
washing or shutdown
Abnormal heating
tube
Continuous heating for 30 minutes,
temperature rise less than 2 degrees
Automatically switch to high water
temperature program or shut down
Abnormal door
lock
Continuous action, or can not be
locked, can not be opened
Restart
Abnormal
communication
Poor contact between display panel
and drive panel
Ask professional maintenance personnel
to check whether the wiring is loose or not.
Note: After checking the above points, there are still abnormalities. Please unplug
the power plug and contact the distributor as soon as possible.
symptom
cause
relief