![Mini-Circuits RCDAT Series User Manual Download Page 31](http://html1.mh-extra.com/html/mini-circuits/rcdat-series/rcdat-series_user-manual_1801824031.webp)
Page 31 of 39
AN-49-005 (December 23, 2019) M176825 (R95497) File: AN-49-005(J).doc
This document and its contents are the property of Mini-Circuits
3.5.4
Configuring units with dynamic addressing
Units connected in Daisy chain configuration can be configured just as when connected
individually to the PC, just select the unit you wish to configure from the drop box, or select ‘ALL’
to set the configuration of all units then configure the unit as described in
section 3.2.3
3.6 Multiple attenuation modes (RCDAT-40G-30)
In the RCDAT-40G-30 you will see below the
connection type on the left side of the
screen options for selecting between two attenuation modes. Mode 1 allows attenuation in 0-30
dB range, 1 dB steps, while mode 2 allows attenuation 0-29, 0.5 dB step. Switching between
modes will reset the attenuation state to the max attenuation allowed in the mode.
Figure 3.5.4:
Configuration screen (with dynamic addressing)
Figure 3.6:
Attenuation modes