KT60443-1G
Sec 3: Mounting Procedure
䚷䚷
3-1. Typical mounting configuration
(1)
(2)
(3)
(4)
(5)
(1)
DY (dynamo)
(2)
Torque transducer TMOFB-*NM
(3)
Coupling (H-flange)
(4)
Flexible coupling
(5)
Intermediate bearing
䚷䚷
3-2. Mounting flange
It may impede the power supply and cause zero balance shift or drifting
when metal objects' is close to the coil which attached to the
periphery of the flange on the equipment.
(1) Mounting unit outer diameter
Measured to the metal rim of the torque transducer flange.
• Ø155 mm max for TMOFB-500NM
䡚
3KNM
• Ø190 mm max for TMOFB-5KNM
(2) Distance from torque transducer flange edge face
At least 8 mm for A type mounting flange configuration (diameter extends to rotor)
At least 15 mm for B type mounting flange configuration (diameter extends to stator)
(3) Distance from torque transducer stator periphery (gap with protective cover etc.)
At least 10 mm from antenna outer diameter
䐟
䐠
䐡
Mounting flange
Coil winding area
Rotor
Stator (antenna)
(1)
(2)
(3)
MinebeaMitsumi Inc. Sensing Device Business Unit