background image

Presented By

Dallas

Houston

Austin

Ft Worth

NicolScales.com

800.225.8181

Contact Us

Nicol Scales & Measurement is an ISO Accredited Calibration 

Company that has provided calibration, repair and sales of all types 

of weighing and measurement products since 1931.

Summary of Contents for Puro EF-LLP1500-3d

Page 1: ...Austin Ft Worth NicolScales com 800 225 8181 Contact Us Nicol Scales Measurement is an ISO Accredited Calibration Company that has provided calibration repair and sales of all types of weighing and measurement products since 1931 ...

Page 2: ...Floor platform Puro Operating Instructions 98628 000 65 Edition 1 0 1 6 22 2020 Minebea Intec Bovenden GmbH Co KG Leinetal 2 37120 Bovenden Germany Phone 49 551 309 83 0 Fax 49 551 309 83 190 ...

Page 3: ...ified personnel In correspondence concerning this product the type name and release number serial number as well as all license numbers relating to the product have to be cited Note This document is partially protected by copyright It may not be changed or copied and it may not be used without purchasing or written permission from the copyright owner Minebea Intec The use of this product constitut...

Page 4: ...3 3 Storage and transport conditions 4 2 4 Failure and excessive stresses 5 3 Device installation 6 3 1 Mechanical preparation 6 3 1 1 Ambient conditions 6 3 1 2 Installation location 6 3 1 3 Unpacking 6 3 1 4 Checking the equipment supplied 7 3 1 5 Leveling the weighing platform 7 3 2 Connection 8 3 2 1 Connecting the platform 8 4 Maintenance repairs cleaning 10 4 1 Repairs 10 4 2 Cleaning 10 4 2...

Page 5: ...involved when measures for preventing hazards are not followed DANGER Warning of personal injury DANGER indicates death or severe irreversible personal injury which will occur if the corresponding safety measures are not observed Take the corresponding safety precautions WARNING Warning of hazardous area and or personal injury WARNING indicates that death or severe irreversible injury may occur if...

Page 6: ...NOTICE indicates that damage to property and or the environment may occur if appropriate safety measures are not observed Take the corresponding safety precautions Note User tips useful information and notes 1 Introduction Floor platform Puro Minebea Intec EN 3 ...

Page 7: ...diately A Minebea Intec sales or service organization must also be notified Visit our website http www puroscales com or contact your dealer 2 3 Before operational startup NOTICE Perform visual inspection Before operational startup as well as after storage or transport inspect the product visually for signs of mechanical damage The product should not be put into operation if it displays signs of v...

Page 8: ...he terminal box or the load receptor during transport Weighing platforms from a size of 1 1 m are equipped with suspension points 2 4 Failure and excessive stresses If the device or the power cord display visible damage Disconnect the power supply and secure the device to prevent it being used further Do not unnecessarily subject the device to extreme temperatures corrosive chemical vapors moistur...

Page 9: ... Extreme temperatures and excessive temperature fluctuations Heat due to proximity to heaters or due to direct sunlight Aggressive chemical vapors Extreme moisture Extreme vibrations 3 1 2 1 Shock resistance NOTICE Falling objects side impacts and shock loads may affect the performance and the accuracy of the scale and damage the platform Avoid shock loads 3 1 3 Unpacking The following applies for...

Page 10: ...f there is damage follow the instructions in the chapter Safety check Keep the original packaging in case the device needs to be returned Remove all cables before sending Use the adjustable feet to align the weighing platform so that the air bubble of the level indicator is in the center of the circle Check that all four of the adjustable feet are touching the surface The weight of the platform mu...

Page 11: ...supply 2 Turn over the indicator 3 Remove the four rubber plugs on the back 4 Loosen the screws underneath 5 Remove the cover 6 Loosen the screw connection 7 Run the load cell cable through the screw connection 8 Secure the wires of the load cell cable into the terminals when doing so pay attention to the pin assignments and the color coding of the connection cable for the platform load cell Floor...

Page 12: ...te n a n a blank EF RRP3000 3d red black green white n a n a blank EF LLS1500 3d red black green white n a n a blank EF NNS1500 3d red black green white n a n a blank EF NNS3000 3d red black green white n a n a blank EF RRS1500 3d red black green white n a n a blank EF RRS3000 3d red black green white n a n a blank 9 Tighten the screw connection 10 Reassemble the housing tighten the screws and app...

Page 13: ...tection grade IP65 or above may also be rinsed with a water jet directed onto the load plate from above If the device is cleaned with water that is too hot or too cold due to temperature differences condensation may form in the device Condensation may cause malfunctions in the device 4 2 2 Cleaning agents NOTICE Some cleaning agents may not be compatible with the device material Only use disinfect...

Page 14: ...ion points run by local public waste disposal companies EU legislation requires its Member States to collect electrical and electronic equipment and dispose of it separately from other unsorted municipal waste so that it can then be recycled Before disposing of or scrapping the product any batteries should be removed and taken to a suitable collection point Please see our T Cs for further informat...

Page 15: ...ent ral load 150 of the max load of the scale Safe overload range cor ner load 50 of the max load of the scale Safe overload range side load 100 of the max load of the scale Leveling aids Externally visible level indicator and adjustable leveling feet Feet 4 adjustable leveling feet Operating temperature C 10 40 Storage temperature C 30 70 Protection grade of the load cell s IP67 Excitation voltag...

Page 16: ... ground stainless steel for platform dimensions 1 250 x 1 250 mm YP PFS2 Frame for pit installation for ground stainless steel for platform dimensions 1 500 x 1 500 mm YP PFS3 Ramps Ramp for ground painted for platform dimensions 1 000 x 1 000 mm YP RFP1 Ramp for ground painted for platform dimensions 1 250 x 1 250 mm YP RFP2 Ramp for ground painted for platform dimensions 1 500 x 1 500 mm YP RFP3...

Page 17: ...6 3 Dimensions EF LLP 1500 All dimensions in mm EF LLS 1500 All dimensions in mm Floor platform Puro 6 Technical data EN 14 Minebea Intec ...

Page 18: ...EF NNP 1500 3000 All dimensions in mm EF NNS 1500 3000 All dimensions in mm 6 Technical data Floor platform Puro Minebea Intec EN 15 ...

Page 19: ...EF RRP 1500 3000 All dimensions in mm EF RRS 1500 3000 All dimensions in mm Floor platform Puro 6 Technical data EN 16 Minebea Intec ...

Page 20: ...Published by Minebea Intec Bovenden GmbH Co KG Leinetal 2 37120 Bovenden Germany Phone 49 551 309 83 0 Email info minebea intec com www minebea intec com ...