background image

Hygienic Weighing Module Contego®

Quick guide

Translation of the quick guide

9499 059 04100

Edition 1.0.6

01/25/2019

Minebea Intec GmbH, Meiendorfer Str. 205 A, 22145 Hamburg, Germany

Phone: +49.40.67960.303 Fax: +49.40.67960.383

Summary of Contents for Hygienic Weighing Module Contego

Page 1: ...eighing Module Contego Quick guide Translation of the quick guide 9499 059 04100 Edition 1 0 6 01 25 2019 Minebea Intec GmbH Meiendorfer Str 205 A 22145 Hamburg Germany Phone 49 40 67960 303 Fax 49 40...

Page 2: ...ied personnel In correspondence concerning this product the type name and release number serial number as well as all license numbers relating to the product have to be cited Note This document is par...

Page 3: ...Table of contents 1 General information 2 2 Assembly 3 2 1 Safety instructions 3 2 2 Mounting the weighing module 4 Hygienic Weighing Module Contego Table of contents EN 1 Minebea Intec...

Page 4: ...ghing module Contego mounting operation A detailed description is given in the installation manual Make absolutely sure you follow the safety instructions in the installation manual Hygienic Weighing...

Page 5: ...id shock stress falling down hard shocks The load cell must be installed vertically and centrally in the mounting kit Load forces must act in the measuring direction of the load cell The load disc mus...

Page 6: ...ting the weighing module The operations must be performed at all supporting points e g vessel foot of the weighing object e g vessel 1 Check if all threaded holes required for mounting in the vessel f...

Page 7: ...It is essential to observe the tightening torques of the screws and the property classes of the screws 4 and washers 4 see installation manual 5 Position the vessel on the bottom 2 Assembly Hygienic W...

Page 8: ...and load cell 6 Mark the boreholes and the seating outline of the lower plate on the foundation 7 Lift the vessel 8 Make the boreholes for the threaded pins stud bolts Hygienic Weighing Module Contego...

Page 9: ...manual 10 Place the adapter plate onto the bottom within the circumferential marking and fasten it with screws It is essential to observe the tightening torques of the screws and the property classes...

Page 10: ...the bottom plate It is essential to observe the tightening torques of the screws and the property classes of the screws 4 and washers 4 see installation manual 13 Remove the auxiliary mounting plates...

Page 11: ...f the lift of protector 15 Slowly turn the threaded bolt of the lift of protector at the hex downwards until it stops to lower the vessel onto the load cell 2 Assembly Hygienic Weighing Module Contego...

Page 12: ...1 1 revolutions approx 2 mm to adjust the spacing 17 Re tighten the nut of the lift of protector It is essential to observe the tightening torques see Installation Manual Hygienic Weighing Module Cont...

Page 13: ...heck whether shaft or and roller can move freely 19 Loosen screws 20 Shift the stopper until shaft or and roller can move freely again 21 Re tighten the screws It is essential to observe the tightenin...

Page 14: ...rom the vessel foot 23 Fit the bellow press it irmly into the groove of the upper and lower plate circumferentially and make sure that the transitions are lush Hygienic Weighing Module Contego 2 Assem...

Page 15: ......

Page 16: ...Published by Minebea Intec GmbH Meiendorfer Strasse 205 A 22145 Hamburg Germany Phone 49 40 67960 303 Email info minebea intec com www minebea intec com...