9.9.1
Target of zero tracking (TARGET OF ZERO TRACKING)
The target of zero tracking can be selected from [GROSS / NET] or [GROSS].
[GROSS] is selected as default.
When [GROSS / NET] is selected, the weighing value both of gross and net become the
target for zero tracking.
9.9.2
Coeicient of data width for zero tracking (ZERO TRACKING BAND)
The coeicient of data width for zero tracking is set in order to set the operative condition
of zero tracking.
The setting is input with ten keys in the range from 0.0 to 9.9 in every 0.1 d.
When [0.0] is set, the zero tracking turns of.
[0.0] is set as default.
For example:
The data width for zero tracking with the coeicient of zero tracking data width is set.
The zero tracking data width per the setting value [n] is calculated in the display
conversion as follows:
Zero tracking data width = Coeicient of zero tracking data width (n) x Scale interval
(Division)
When the setting of coeicient of zero tracking data width is [5.0] and the divition is [D =
5]:
Zero tracking data width = 5.0 x 5 d = 25.0 d
9.9.3
Time of zero tracking (ZERO TRACKING TIME)
The time of zero tracking is set in order to set the operative condition of zero tracking.
The setting is input with ten keys in the range from 0.0 to 9.9 in every 0.1 seconds.
When [0.0] is set, the zero tracking turns of.
[0.0] is set as default.
+Zero tracking
data width
Zero point
Time
- Zero tracking
data width
Zero tracking width
Zero tracking width
Zero tracking width or less
Zero tracking width
Display
9 Basic function setting display (BASIC FUNCTION)