Judge
Waiting timer for judge
Stable
Fein flow
Middle flow
Coarse flow
Finish
Batch start
Final(Setpoint) – Coarse Flow
Final(Setpoint) – Middle Flow
Final(Setpoint) – Fine Flow
Final (Setpoint)
0
Weighing
Nozzle down
by batch start
Nozzle down
Batch start delay
Time
Nozzle is up
after Fine Flow closed
11.6.5
Automatic Free Fall correction
This is a function to guess the next Free Fall from a former actual Free Fall, and to set the
value of the Free Fall automatically when the measurement is operated continuously.
The set data of the next Free Fall uses the moving averaged value calculated from 4 times
of actual former Free Fall values.
When using the function, set the Automatic Free Fall correction to [EFFECTIVE] (refer to
Chapter
), and also set the value of Automatic Free Fall efective width in each Brand
(refer to Chapter
When the Batch error ( = ?measured value - FINAL value?) is exceeded to the Automatic
Free Fall efective width set at each BRAND, the data is treated as invalid data, and the
Automatic Free Fall calculation is not operated.