Weighing
Gross
Net
0
Time
Final (Setpoint)
Setpoint – Fine Flow
Setpoint – Middle Flow
Setpoint – Coarse Flow
Zero band
Batch start
Batch start delay time
Set of control
Coarse Flow : Fixed open (weight)
Middle Flow : Fixed open (weight)
Fine Flow : Fixed open (weight)
Batch start time
Coarse flow
Middle flow
Fine flow
Coarse flow weighing
stop timer
Middle flow weighing
stop timer
Fine flow weighing
stop timer
Waiting time for judge
Stable
Finish
+tolerance (over setpoint)
-tolerance (under setpoint)
OK
Discharge starts
Discharge
Discharge gate close
delay
Discharge finishes
Zero band
Discharge monitoring timer
Batch finish output on
Can be tare at the same time depends on settings.
Judge
Can be changed to
simple comparative
11.6.2
Sequential batching mode
The sequential batching mode is to control the weighing sequence by the decrease value
of weighed value or the control time when the weighing object is baching out.
11 Weighing mode
Weight Controller CSD-918
Minebea Intec
EN-109
Summary of Contents for CSD-918 Series
Page 239: ......