MindWare Wireless Data Center Hardware 

50-6030-00 

User Reference Guide 

 

Copyright 2015 © by MindWare Technologies LTD. All Rights Reserved. 

 

 

 

 

 

Summary of Contents for 50-6030-00

Page 1: ...MindWare Wireless Data Center Hardware 50 6030 00 User Reference Guide Copyright 2015 by MindWare Technologies LTD All Rights Reserved ...

Page 2: ...ation Rd Gahanna OH 43230 2 Internet Support E mail sales mindwaretech com Web Address www mindwaretech com Phone Ph 614 626 4888 Fax 614 626 4915 MindWare Technologies LTD 1020F Taylor Station Rd Gahanna Oh 43230 Copyright 2015 by MindWare Technologies LTD All Rights Reserved ...

Page 3: ... potential for death or bodily injury caused by product failure or by errors on the part of the user or application designer Any use or application of MindWare Technologies LTD products for or involving medical or clinical treatment must be performed by properly trained and qualified medical personnel and all traditional medical safeguards equipment and procedures that are appropriate in the parti...

Page 4: ...hanna OH 43230 4 Table of Contents Section 1 Technical Specifications 5 Section 2 Instructions For Use 7 Warnings 7 Hardware Setup 7 Identification of Operating Controls 7 Accessories and Consumables 8 Section 3 Rear Panel 9 Rear Panel 9 Front Panel 10 Section 4 Cleaning Instructions 12 ...

Page 5: ...ure up to 31 C decreasing linearly to 50 at 40 C Power supply voltage fluctuations not to exceed 10 of the nominal voltage Over voltage category II Pollution degree 2 Input Voltage Range AC Input 100 240VAC 50 60Hz 1A 115VAC Fuse Characteristics 2A T 250V 5X20mm Analog Inputs 2 Channels 12 Bit 10 kS s 10V Digital Inputs 4 Asynchronous Inputs 500 S s 10 0 8V Input Low Voltage 2 0V Input High Voltag...

Page 6: ... Optimized for MindWare Mobile WiFi data 9 RJ45 Ethernet Ports 10 100 Auto MDI X 7 Front LAN 1 Rear LAN DHCP enabled 1 Front WAN NAT DHCP Client Wireless 802 11g 2 4GHz Automatic channel selection Bridged to LAN Audio and Video Up to 4 A V channels 75ohm BNC video 30fps NTSC 25fps PAL Stereo RCA line level audio ...

Page 7: ...lectric shock If any equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Hardware Setup Connect the provided Ethernet cable to any of the numbered ports on the Wireless Data Center and the Ethernet port on the PC Connect the provided USB cable between the USB port on the Wireless Data Center and a USB 2 0 port on the PC Attach th...

Page 8: ... Connect the DB25 connector to the parallel port of the computer with E Prime installed Desktop Kit Part 50 6032 00 Instructions Turn power to the Wireless Datacenter hardware off Unplug the power cable from the Wireless Datacenter Attach feet to embedded nuts on bottom of unit using provided screws Do not over tighten 2A T 250 V 5X20 mm Slow Blow Fuse Part 55 0834 00 Instructions Turn power to th...

Page 9: ...Ph 614 626 4888 Fax 614 626 4915 www mindwaretech com 9 Section 3 Rear Panel Rear Panel Power Switch Fuseholder AC Input Rear LAN Interface Stereo Audio Channels 1 4 ...

Page 10: ...ylor Station Rd Gahanna OH 43230 10 Front Panel Antenna Analog Input 3 5mm Tip Channel 1 Shaft Channel 2 Base Ground Digital DB9 Pins 1 4 Digital Channels 1 4 Pins 5 7 Unconnected Pin 8 5V 100mA max output Pin 9 Ground Trigger RCA 0 5V range Software configured behavior ...

Page 11: ...N 1 7 RJ45 Data collection computer and network camera interface 100Mbit Auto MDI X Ethernet DHCP enabled WAN RJ45 Connection to external network 100Mbit Auto MDI X Ethernet DHCP client NAT connection to LAN WARNING Excess network traffic can interfere with research data collection Not recommended for use during data collection Antenna ...

Page 12: ... surfaces With an eraser gently rub across the scratch Clean off any debris before using Cleaning Hardware Turn the power to the Wireless Data Center off Disconnect the power and all other cables connected to the device With a slightly damp cloth wipe off hardware Avoid getting moisture in exposed connectors Allow to dry thoroughly before reconnecting power ...

Page 13: ...Ph 614 626 4888 Fax 614 626 4915 www mindwaretech com 13 1020 F Taylor Station Road Gahanna OH 43230 614 626 4888 www mindwaretech com Copyright 2015 MindWare Technologies LTD ...