background image

 

94 

 

Multiple-scan setting 

Single-scan setting 

Option barcode 

Option 

Alpha. entry 

Prefix string setting 

 

0-22 characters 

00-FF

16

 

 

None 

00* 

Suffix string setting 

 

0-22 characters 

00-FF

16

 

 

<ENTER> 

0D0A* 

 

Preamble string setting 

 

0-22 characters 

00-FF

16

 

 

none 

00* 

Postamble string setting 

 

0-22 characters 

00-FF

16

 

 

none 

00* 

Insert G1 string setting 

 

0-22 characters 

00-FF

16

 

 

none 

00* 

Insert G2 string setting 

 

0-22 characters 

00-FF

16

 

 

none 

00* 

Insert G3 string setting 

 

0-22 characters 

00-FF

16

 

 

none 

00* 

Insert G4 string setting 

 

0-22 characters 

00-FF

16

 

 

none 

00* 

FN1 substitution string setting 

 

0-4 characters 

00-FF

16

 

 

<SP> 

20* 

Summary of Contents for ES4650

Page 1: ...ES4650 Embedded Image Scanner User Manual Version ES4650_UM_EN_V1 1 1...

Page 2: ......

Page 3: ...down pin TRIG 12 2 6 4 Decode by commands 13 3 Parameter menus 14 3 1 Introduction 14 3 2 Example 1 Single parameter setting by scanning 1D barcodes 15 3 3 Example 2 Multiple parameter setting by sca...

Page 4: ...89 3 43 GM code 90 3 44 G1 G6 C1 C2 FN1 substitution string setting 91 3 45 G1 G4 string position Code ID position 96 3 46 String transmission 97 4 Serial Communication Interface SCI 100 4 1 Programmi...

Page 5: ...iii 10 Return default parameters firmware version 116 11 Configuration alphanumeric entry barcode 117...

Page 6: ...iv Notes about structure and electric circuit design 1 The embedded scanner must be electrically isolated 2 Leave sufficient space to accommodate the maximum size of the embedded scanner...

Page 7: ...2 of 5 Industrial 2 of 5 Matrix 2 of 5 Codabar NW7 Code 128 ISBT 128 Code 93 Code 11 USD 8 MSI Plessey UK Plessey UCC EAN 128 GS1 128 China Post China Finance Telepen GS1 DataBar formerly RSS variant...

Page 8: ...064 2 27 Shock pulse 0 5 ms Maximal acceleration 1500 G Shock direction time X axis Y axis Z axis 3 times for each direction total of 18 times Safety Photobiological Safety EN62471 2008 EMC EN55022 ES...

Page 9: ...of 5 6 I Im Industrial 2 of 5 4 H S0 Matrix 2 of 5 6 X X0 Codabar 4 N Fm Code 128 1 K Cm UCC EAN 128 GS1 128 1 K Cm ISBT 128 1 K Cm Code 93 1 L Gm Code 11 4 V H3 MSI Plessey 4 O Mm UK Plessey 1 U Mm C...

Page 10: ...ID AIM Code ID CodaBlock F Code4 c Om GM code4 g Note 1 The settings for ISBN ISSN and EAN 13 must be the same except the Code ID 2 Fixed length barcodes 3 The settings for GS1 DataBar Truncated and...

Page 11: ...5 2 Getting started 2 1 Parts of scanner Figure 2 1 Appearance Beeper Trigger CMOS sensor...

Page 12: ...nput Ground for interface auto selection Input RS 232 Logic high level 3 3V USB Logic low level 0V reference 5 TXD Output NC RS 232 Serial data transmit output port Transmitted data 6 RXD Input NC RS...

Page 13: ...unconnected or tied to VCC by 100K Ohm resistors when they are not used The following diagram demonstrates the interconnection TXD CTS RTS RXD Host TXD Host CTS Host RTS Host RXD Embedded scanner Host...

Page 14: ...ut each output port is an open drain pad with a 100K Ohm pull up resistor and the maximum sink current is 100 mA VCC 3 3V 100K VCC Embedded scanner OUTPUT External LDO circuitry it is recommended to a...

Page 15: ...9 2 4 Installation guide 2 4 1 Mounting Units mm...

Page 16: ...ngle 23 24 24 24 24 25 25 D Placing the scan window vertically is feasible NO A Scan Window Distance from Scanner mm 14 15 16 17 18 19 20 B Max Positive Angle 25 25 24 23 23 22 21 C Min Negative Angle...

Page 17: ...o low fall time CL 50pf 1 0 us Trigger timing ttrig_1 Trigger low level hold time 20 ms ttrig_h Trigger high level hold time 20 ms tdbt Trigger de bounce time 1 1 ms Wake up timing tidle2fo Idle to Op...

Page 18: ...t sends a Firmware Version list command 0x16 0x4D 0x0D 0x25 0x25 0x25 0x56 0x45 0x52 0x2E 2 After receiving the command Embedded Scanner responds with firmware version RXD Host TXD TXD Host RXD REQUES...

Page 19: ...character Host sends a START_DECODE command 0x16 0x54 0x0D 4 Embedded Scanner turns on LED illumination to decode The LED illumination will be turned off if either Scan standby duration expires or Emb...

Page 20: ...luded in this section The new values replace the existing values To set the new values as custom default settings scan the Write to Custom Defaults barcode The factory default settings or custom defau...

Page 21: ...ample To set Flow control to be XON XOFF Steps Scan the following barcode Multiple scan setting Step 1 Scan the Option barcode barcode e g 0101M according to the user s demand Step 2 To the right of t...

Page 22: ...aracter string with various length of 2 4 or other values Example Set 0401 03 decimal 8002 0D0A hexadecimal 8202 01 decimal The customized QR code barcode contents and symbol are as following 0401D03...

Page 23: ...e to transmit XON XOFF An XOFF character turns the embedded scanner s transmission off unit the embedded scanner receives an XON character ACK NAK After transmitting data the embedded scanner expects...

Page 24: ...ption Alpha entry Flow control None 00 RTS CTS 01 Two direction flow control 02 XON XOFF 03 ACK NAK 04 Inter character delay 0 ms 00 5 ms 01 10 ms 02 20 ms 03 40 ms 04 80 ms 05 Response delay 00 99 10...

Page 25: ...iple scan setting Single scan setting Option barcode Option Alpha entry 9600 05 19200 06 38400 07 57600 08 115200 09 Parity bit None 00 Odd 01 Even 02 Data bit 8 bits 00 7 bits 01 Stop bit 1 bit 00 2...

Page 26: ...he embedded scanner automatically restarts 2 USB Device Type will be changed to USB virtual COM if Scan Mode is set as Host Besides the change of USB Device Type from the USB virtual COM to others is...

Page 27: ...ice type HID keyboard 00 HID keyboard for Apple Mac 01 USB virtual COM 02 Simple COM Port Emulation 03 Keyboard layout USA 00 Turkish F 01 Turkish Q 02 French 03 Italian 04 Spanish 05 Slovak 06 Denmar...

Page 28: ...22 Multiple scan setting Single scan setting Option bar code Option Alpha entry 10 ms 02 20 ms 03 40 ms 04 60 ms 05 Numeric key Alphabetic key 00 Numeric keypad 01 Alt keypad 02...

Page 29: ...moved to enable Auto detection Auto detection Good read on By setting Enable the scanner will start scanning if any nearby object has been detected The scanner stops scanning when no code is successfu...

Page 30: ...decoder with error correction This function is not effective for all types of barcode Data output delay in continue scan mode If it is enabled in the continue scan mode the scanner can store the data...

Page 31: ...off 00 Momentary 01 Alternate continue 02 Continue 03 Time out off 04 Host 05 Auto detection Good read on 06 Auto detection Good read off 07 Auto detection sensitivity 5 00 10 01 15 02 20 03 25 04 30...

Page 32: ...07 5 minutes 08 7 minutes 09 10 minutes 10 15 minutes 11 20 minutes 12 30 minutes 13 45 minutes 14 1 hour 15 Same barcode delay time for 1D symbol 00 FF16 50 ms 00 FF16 00 08 Same barcode delay time...

Page 33: ...1 Character output restraint None 00 Printable character only 01 Alphanumeric character only 02 Decoder optimization Disable 00 Enable 01 Data output delay in continue scan mode 00 99 100 ms FF Never...

Page 34: ...gle scan setting Option barcode Option Alpha entry 10 seconds 02 30 seconds 03 60 seconds 1 minute 04 300 seconds 5 minutes 05 600 seconds 10 minutes 06 1800 seconds 30 minutes 07 3600 seconds 1 hour...

Page 35: ...canner will beep to indicate a good barcode reading and its beep tone duration is adjustable Beep on BEL Character The embedded scanner will beep upon a BEL 0x07 character from the host if it is enabl...

Page 36: ...this option is enabled the embedded scanner will project the aiming pattern during the code capture Level of decode illumination This parameter can be adjusted for different level of decode illuminat...

Page 37: ...s On 01 Flashing 02 On when reading 03 Decode aiming pattern Always off 00 Always on 01 On before reading 02 On when reading 03 Level of decode illumination Disable decode illumination 00 Low 01 Middl...

Page 38: ...tting enable the embedded scanner allows to read multiple symbols in one image By setting Disable the embedded scanner will only read the symbol closest to the center area in the image Vertical center...

Page 39: ...e 01 All 1D Enable 02 2D symbols read Follow respective 2D symbol setting 00 All 2D Disable 01 All 2D Enable 02 Only PDF417 Enable 03 Only QR code Enable 04 Only Data Matrix Enable 05 Only MaxiCode En...

Page 40: ...le maintaining the distance of about 15cm between the exit window of the embedded scanner and this paper After a few seconds the embedded scanner will give three short beeps to indicate a successful c...

Page 41: ...coded The symbol types which support Structured Append include QR code Aztec code PDF417 and DataMatrix The lower part of below figure shows an example of four Structured Append symbols with the same...

Page 42: ...ultiple scan setting Single scan setting Option barcode Option Alpha entry DPM format read Disable 00 Enable 01 Structured append symbols read Disable 00 Enable 01 Mobile screen read Disable 00 Enable...

Page 43: ...Supplement digits barcode is the supplemental 2 of 5 characters Format System character Data digits 10 digits Check digit Supplement digits 2 of 5 Truncation Expansion Truncate leading zeros The lead...

Page 44: ...Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 A Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digi...

Page 45: ...eros The leading 0 digits of UPC E data characters can be truncated when the feature is enabled Example Barcode 00123457 Output 123457 Expand to EAN 13 It extends to 13 digits with a 0 leading digit w...

Page 46: ...0 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 D Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digits 03 Trun...

Page 47: ...gits Check digit Supplement digits 2 of 5 Truncation Expansion Expand to EAN 13 It extends to 13 digits with 0 digits when the feature is enabled Example Barcode 10012341 Output 0100120000031 Expand t...

Page 48: ...ion Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 D Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 d...

Page 49: ...SBN international Standard Book Number or Bookland EAN and ISSN International Standard Serial Number are two kinds of barcode for books and magazines The ISBN is 10 digits with leading 978 and the ISS...

Page 50: ...etting Option barcode Option Alpha entry Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 01 5 digits 02 2 or 5 digits 03 ISBN ISSN conversion Disable 00 Enable 01 ISBN ISSN Co...

Page 51: ...By setting Enable check digit will be transmitted Code ID setting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of 3 11 UPC A Supplement digits F...

Page 52: ...Check digit verification Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Code ID setting 00 FF16 ASCII 00 FF16 C Insert group selection 00 66 00 66 00 Supplement digits None 00 2 digits 0...

Page 53: ...h barcode decoded Code ID setting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of 3 11 UPC A Start End transmission The start and end characters...

Page 54: ...1 Check digit verification Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 M Insert grou...

Page 55: ...Option Alpha entry as data character Disable 00 Enable 01 Convert Code 39 to Code 32 Disable 00 Enable 01 Code 32 prefix A transmission Disable 00 Enable 01 Trioptic Code 39 read Disable 00 Enable 01...

Page 56: ...ptional check digit algorithms the specified Uniform Symbol Specification USS and the Optical Product Code Council OPCC Check digit trans By setting Enable check digit will be transmitted Max Min code...

Page 57: ...Alpha entry Read Disable 00 Enable 01 Check digit verification Disable 00 USS 01 OPCC 02 Check digit trans Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 06 Code ID se...

Page 58: ...ting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of 3 11 UPC A Multiple scan setting Single scan setting Option barcode Option Alpha entry Read...

Page 59: ...dule 10 of the numerical value of the data digits Check digit trans By setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of 3 16 Code 39 Code 32 Trioptic...

Page 60: ...n Alpha entry Read Disable 00 Enable 01 Check digit verification Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 06 Code ID setti...

Page 61: ...n group selection Refer to Insertion group selection of 3 11 UPC A Start End Type Codabar has four pairs of Start End Pattern you may select one pair to match your application Start End transmission R...

Page 62: ...Option Alpha entry Code ID setting 00 FF16 ASCII 00 FF16 N Insert group selection 00 66 00 66 00 Start End type ABCD ABCD 00 abcd abcd 01 ABCD TN E 02 abcd tn E 03 Start End transmission Disable 00 E...

Page 63: ...tting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of 3 16 Code 39 Code 32 Trioptic Code 39 Code ID setting Refer to Code ID setting of 3 11 UPC A Insertion...

Page 64: ...e 01 Check digit verification Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 K Insert g...

Page 65: ...igits Check digit trans By setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of 3 16 Code 39 Code 32 Trioptic Code 39 Code ID setting Refer to Code ID set...

Page 66: ...e 01 Check digit verification Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 ASCII 00 FF16 K Insert g...

Page 67: ...the sum module 103 of all data digits Check digit trans By setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of 3 16 Code 39 Code 32 Trioptic Code 39 Code...

Page 68: ...n Alpha entry Read Disable 00 Enable 01 Check digit verification Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setti...

Page 69: ...the sum module 47 of all data digits Check digit trans By setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of 3 16 Code 39 Code 32 Trioptic Code 39 Code...

Page 70: ...n Alpha entry Read Disable 00 Enable 01 Check digit verification Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setti...

Page 71: ...is made as the sum module 11 of all data digits Check digit trans By setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length of 3 16 Code 39 Code 32 Trioptic Co...

Page 72: ...n Alpha entry Read Disable 00 Enable 01 Check digit verification Disable 00 1 digit 01 Check digit trans Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 00 Code ID sett...

Page 73: ...s i e Mod 10 Mod 10 10 and Mod 10 11 The check digit1 and check digit 2 will be calculated as the sum module 10 or 11 of the data digits Check digit trans By setting Enable check digit will be transmi...

Page 74: ...00 Enable 01 Check digit verification Disable 00 1 digit Mod 10 01 2 digits Mod 10 10 02 2 digits Mod 10 11 03 Check digit trans Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00...

Page 75: ...and check digit 2 will be calculated as the sum module 10 or 11 of the data digits Check digit trans By setting Enable check digit will be transmitted Max Min code length Refer to Max Min code length...

Page 76: ...n Alpha entry Read Disable 00 Enable 01 Check digit verification Disable 00 Enable 01 Check digit trans Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setti...

Page 77: ...fer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of 3 11 UPC A Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable...

Page 78: ...to Max Min code length of 3 16 Code 39 Code 32 Trioptic Code 39 Check digit verification The check digit is calculated as the sum module 10 of the data digits Leading character 5 6 7 8 9 converted to...

Page 79: ...length 00 99 00 99 10 Check digit verification Disable 00 Reserved 01 Leading character 5 6 7 8 9 converted to A B C D E Disable 00 Enable 01 Only 5 converted to A 02 Only 6 converted to B 03 Only 7...

Page 80: ...n barcode Option Alpha entry Assigned to 6 B 03 Assigned to 7 C 04 Assigned to 8 D 05 Assigned to 9 E 06 Assigned to 1 07 Assigned to 2 08 Assigned to 3 09 Assigned to 4 10 Code ID setting 00 FF16 ASC...

Page 81: ...to Max Min code length of 3 16 Code 39 Code 32 Trioptic Code 39 Code ID setting Refer to Code ID setting of 3 11 UPC A Insertion group selection Refer to Insertion group selection of 3 11 UPC A Encode...

Page 82: ...0 Enable 01 Check digit verification Disable 00 Enable 01 Check digit transmission Disable 00 Enable 01 Max code length 00 99 00 99 00 Min code length 00 99 00 99 01 Code ID setting 00 FF16 00 FF16 P...

Page 83: ...A Conversion UCC EAN 128 Refer to Code ID transmission of 3 46 String transmission Cm will be identified as AIM ID UPC A or EAN 13 Barcode beginning with a single zero as the first digit has the leadi...

Page 84: ...Insertion group selection of 3 11 UPC A Conversion Refer to Conversion of 3 31 GS1 DataBar GS1 DataBar Truncated Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disabl...

Page 85: ...lection of 3 11 UPC A Conversion Refer to Conversion of 3 31 GS1 DataBar GS1 DataBar Truncated Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01 Max...

Page 86: ...C up to 2361 digits GS1 128 Composite GS1 DataBar Stacked Composite GS1 DataBar Expanded Stacked Composite GS1 DataBar Composite UPC E Composite EAN 13 Composite GS1 composite version enabled Note 1...

Page 87: ...ta GS1 128 Composite DataBar Composite Two versions of GS1 Composite symbol are enabled GS1 128 Composite DataBar Composite UPC EAN Composite Three versions of GS1 Composite symbol are enabled Multipl...

Page 88: ...82 3 35 PDF417 Read Format Data digits variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Page 89: ...83 3 36 MicroPDF417 Read Format Data digits variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Page 90: ...84 3 37 QR Code Read Format Data digits variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Page 91: ...85 3 38 Data Matrix Read Format Data digits variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Page 92: ...de Note The support for this feature is available with customized firmware version Read Format Data digits variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Dis...

Page 93: ...87 3 40 Aztec Code Read Format Data digits variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disable 00 Enable 01...

Page 94: ...de Note The support for this feature is available with customized firmware version Read Format Data digits variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Dis...

Page 95: ...Code Note The support for this feature is available with customized firmware version Read Format Data digits variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read D...

Page 96: ...Note The support for this feature is available with customized firmware version Read Format Data digits variable Multiple scan setting Single scan setting Option barcode Option Alpha entry Read Disab...

Page 97: ...coded Example Add a symbol of as a prefix for all symbols Steps 1 Scan the option barcode of Prefix string setting 8001M 2 Use the 8 ASCII table to find the value of 24 3 Scan 2 and 4 4 Scan END barco...

Page 98: ...while the option of Truncate leading G5 string setting is 00 Example Truncate all leading zeros for all symbols Original code data 0 0 0 1 2 3 4 5 6 Output code data 1 2 3 4 5 6 Steps scan the followi...

Page 99: ...ltaneously Example Replace all the A character in a data string to be B character Original code data 1 2 3 A 5 A Output code data 1 2 3 B 5 B Steps scan the following barcodes in order The ASCII value...

Page 100: ...le string setting 0 22 characters 00 FF16 none 00 Postamble string setting 0 22 characters 00 FF16 none 00 Insert G1 string setting 0 22 characters 00 FF16 none 00 Insert G2 string setting 0 22 charac...

Page 101: ...of a G5 character setting Defined times 01 22 Once 01 Un defined times All FF Truncate ending G6 string setting 1 22 defined characters 01 7F16 A un defined character 00 0 30 Repeat of a G6 character...

Page 102: ...f the insertion position is greater than the length of the symbol the insertion of string is not affected Code ID position It is allowed to select different positions of Code ID placement Multiple sca...

Page 103: ...a string can be transmitted before the code data transmitted when Enable is selected The length is represented by a number with two digits Case conversion The characters within code data or the whole...

Page 104: ...ssion Disable 00 Enable 01 Code name transmission Disable 00 Enable 01 Preamble transmission Disable 00 Enable 01 Postamble transmission Disable 00 Enable 01 Code ID transmission Disable 00 Enable 01...

Page 105: ...etting Option barcode Option Alpha entry All non printable character string transmission with string setting Disable 00 Enable 01 Transmit the first N data characters only 01 99 All 99 Transmit the la...

Page 106: ...ommunication Interface SCI The function of the SCI show as below Maintain a bi directional communication interface between the embedded scanner and the host Allow the host to send commands to access t...

Page 107: ...etting parameters e g Prefix string setting Storage A single character that specifies the storage area to which the command is applied to An exclamation point performs the command s operation on the v...

Page 108: ...e Set 0401 03 decimal 8002 0D0A hexadecimal The command is as following Prefix Parameter index D Value Parameter index H Value 0x16 0x4D 0x0D 0x30 0x34 0x30 0x31 0x44 0x30 0x33 0x3B 0x38 0x30 0x30 0x3...

Page 109: ...x25 0x25 0x44 0x45 0x46 0x2E Set the parameters to the default values Write to Custom Defaults Format SYN M CR WCDF 0x16 0x4D 0x0D 0x25 0x25 0x57 0x43 0x44 0x46 0x2E Write the current parameter settin...

Page 110: ...e Ship Format SYN M CR DISHP 0x16 0x4D 0x0D 0x25 0x44 0x49 0x53 0x48 0x50 0x2E An image is taken whenever the scan operation is done The last image is always stored in memory The down sampled image ca...

Page 111: ...esponse with 8001H314E ACK Host SYN M CR 8001H314E Embedded Scanner 8001H314E 8001 H 314E ACK 0x38 0x30 0x30 0x31 0x48 0x33 0x31 0x34 0x45 0x06 Step 2 1 Enable Prefix transmission 2 Look up the parame...

Page 112: ...s decimal thus D is used 3 The value field is filled with 4 Put all above parts and then append a storage indicator to construct the command SYN M CR 0401 5 Upon receiving command embedded scanner res...

Page 113: ...Enable Disable NR Enable NR If it is enabled while the scanner receives the STOP_DECODE command or fails to decode a barcode within the Stand by duration time the scanner will transmit NR Disable NR D...

Page 114: ...t The default status of the embedded scanner is enabled to scan configuration barcode Disable configuration by scanning barcode Scan the above barcode to disable scanning configuration barcode then th...

Page 115: ...ode is different 2 If using CODESOFT software firstly read the information through Help Index Code128 Special input syntax Also refer to ASCII table For example if we wish to make F1 barcode select CO...

Page 116: ...8 BS CAN 9 Tab F9 HT EM A F10 LF SUB B Home Esc VT ESC C End F11 FF FS D Enter F12 CR GS E Insert Ctrl SO RS F Delete Alt SI US Notes The 2nd and the 3rd columns above are used for keyboard wedge only...

Page 117: ...bols UPC A UPC E UPC E1 Default setting Disable EAN 13 ISBN ISSN EAN 8 Code 39 Code 32 A908765439 Trioptic Code 39 Default setting Disable Interleaved 2 of 5 Industrial 2 of 5 Default setting Disable...

Page 118: ...C EAN 128 ISBT 128 Code 93 Code 11 Default setting Disable MSI Plessey Default setting Disable UK Plessey Default setting Disable China Post Telepen GS1 DataBar GS1 DataBar Truncated GS1 DataBar Limit...

Page 119: ...113 PDF417 12 890ab xyz MicroPDF417 0239 mdo QR code 1234567890ABCD XYZ Data Matrix 123890abc mdo...

Page 120: ...114 Aztec Code Default setting Disable 12345678901234567890 Han Xin Code Default setting Disable SAMPLE...

Page 121: ...115 Micro QR Default setting Disable 0123456789MINDEO CodaBlock F Code 0123456789 GM Code 0123456789MINDEO...

Page 122: ...actory default values Write to Custom Defaults Store the current scanner settings as custom defaults Restore Custom Defaults Restore the scanner s custom default settings If no custom defaults were se...

Page 123: ...117 11 Configuration alphanumeric entry barcode To finish parameter setting please scan the bar code below...

Reviews: