Minco TT269 Installation And Operating Instructions Download Page 1

MINCO

TT269

3-wire Temperature Transmitter

Installation and Operating Instructions

Description

Model TT269 is a 3-wire temperature transmitter for RTD (resistance temperature detector)
thermometers.  The Temptran

TM

 converts the  RTD's signal into a 0 to 1 mA current.  The

current changes according to the range marked on the Temptran: 0 mA at the lowest
temperature of the range, rising to 1 mA at the top of the range.

Installation

Locate the Temptran near the RTD, in an area where the ambient temperature stays between -
40 and 85 °C (-40 and 185 °F).  Mount with #8 machine screws using the two mounting holes
provided in the Temptran case.

Connect the Temptran as shown below, observing the +/- polarity of the power supply
connections.  Maximum DC supply voltage = 35 VDC.  The maximum load resistance for the 0
to 1 mA output is 1000 

.  The RTD connections for the Temptran in the wiring diagram below

must be connected as shown or the transmitter will not function properly.

Wiring Diagram

 

PRODUCTS, INC

.

  7300 Commerce Lane, Minneapolis, MN 55432-3177  U.S.A.
  Telephone: (763)571-3121    /    FAX: (763)571-0927