15
MM23000 Series drives have six user adjustable trimpots: MIN
SPD, MAX SPD, TORQUE, IR COMP, ACCEL, and DECEL.
Refer to Figure 10, page 16 for trimpot layouts. Each drive is
factory calibrated to its maximum current rating. Readjust the
calibration trimpot settings to accommodate lower current rated
motors.
All trimpot settings increase with clockwise (CW) rotation, and
decrease with counterclockwise (CCW) rotation. Use a non-
metallic screwdriver for calibration. Each trimpot is identified
on the printed circuit board.
Warning
Dangerous voltages exist on the drive when it is powered.
When possible, disconnect the voltage input from the drive
before adjusting the trimpots. If the trimpots must be
adjusted with power applied, use insulated tools and the
appropriate personal protection equipment. BE ALERT.
High voltages can cause serious or fatal injury.
Calibration
All manuals and user guides at all-guides.com
all-guides.com