10
4. Press TRANSFER TO EPM to copy the data from the MASTER EPM to the target EPM
(refer to NOTE 1 below).
5. Remove the target EPM from the EPM PORT. The EPM is now fully programmed and
ready to be installed in a drive.
6. To program another EPM using the same MASTER EPM, simply install another target
EPM in the EPM PORT and repeat step 4.
NOTE 1:
Before the EPM Programmer transfers the data to the target EPM, it will compare
the parameter version of the data file to the parameter version of the target EPM. If they are
different, the version numbers will be displayed as a warning that they are not the same. The
display will then indicate that the command to transfer the data can be confirmed by pressing
the ENTER key. If the data transfer is performed, the target EPM will be converted to the same
parameter version as the transferred data file, which may result in improper drive operation. If
the parameter version of an EPM does not match the parameter version of the drive it is
installed in, the drive will display a “cF” fault and the drive will not operate. Refer to the
AC100 or AC200 Series Installation and Operation Manual for more information on the “cF”
fault.
To cancel the transfer command, press any key other than ENTER. To confirm that the data
transfer is the desired action, press the ENTER key. Once the data has been transferred, the
target EPM will have the same parameter version as the transferred data file.
In the example below, the parameter version of the data file to be transferred is 306, but the
target EPM came from a version 309 drive. Therefore, the EPM Programmer will not transfer
the data unless the ENTER key is pressed to confirm that transferring the data is the desired
action.