Use the Optional Ionizer

5

Alarm output function

This ionizer has the function to output alarms.

Alarm output part

Alarm function

Angle adjustment of the ionizer

Ionizer can be moved.
If it is hard to access to the work at the back side of the table, move the ionizer on the upper side.

Item

Alarm (ALM)

Ion level (ION)

Condition (COND)

Indication

Indicator light blinks three times 
about every second.

Indicator light blinks twice about 
every second.

Indicator light blinks. once about 
every second

Status etc.

Internal circuit has been broken.
Abnormal discharge occurs.

Due to blot on the electrode probe 
and wear of it, ion production has 
decreased.
Use this as a guide for time to 
take care of the electrode probe.

The installed environment 
(temperature, humidity, peripheral 
metals, etc.) have affected the 
performance to remove electricity.

Removing 

electricity

Removing electricity stops.

Removing electricity continues.

Removing electricity continues.

Countermeasure

Contact a distributor in your 
district or our office.

Take care of the electrode 
probe.

*1

If the status cannot be improved, 
replace the relevant electrode 
probe.

*1. Before taking care of the electrode probe, turn off the main power of the main body, and be careful to perform the work.

Check the environment and 
peripheral metals.

Replacement 

part

                                 

SPA-0208
Tungsten electrode probes for 
ionizer (including 4)

                                 

【6042MkII】

【3042MkII】

Indicator 

light

Indicator light

Ionizer

Summary of Contents for UJF-3042MkII EX

Page 1: ...the latest manual from our website Instruction Manual for Ionizer Table of Contents Before using 2 Setting the Ionizer 2 About daily care 2 Cleaning the Electrode Probe 2 Clean with Electrode Probe Cl...

Page 2: ...electrode probe 2 Wipe off the electrode probe and around it with a cotton swab immersed in alcohol Recommended ethyl alcohol isopropyl alcohol It is possible that enough effect cannot be achieved de...

Page 3: ...ion of the filter to be set in 1mm to the end faces Push the filter completely inside to prevent it from bending Do not touch the electrode probe directly You may get injured Be careful to work Do not...

Page 4: ...e used filter and insert the new filter into the hole at the center of the electrode probe cleaning kit 2 Be careful of the way the filter is facing Install the filter with the diagonally tip side up...

Page 5: ...of it ion production has decreased Use this as a guide for time to take care of the electrode probe The installed environment temperature humidity peripheral metals etc have affected the performance t...

Page 6: ...6 UJF 3042 6042MkII UJF 3042 6042MkII ON 1 MENU 2 3 4 ON ON 5 SPA 0237 SPA 0239 1 1 2 2...

Page 7: ...7 SPA 0237 SPA 0237 1 2 2 3 SPA 0237 1 2 1mm SPC 0238 1...

Page 8: ...8 2 SPA 0239 SPA 0237 2 SPA 0239 1 2 2 2 2 3 2 2 SPA 0239 1 2 2 0 2mm 2 2 SPC 0240 1...

Page 9: ...9 ALM ION COND 1 3 1 2 1 1 1 1 SPA 0208 4 6042MkII 3042MkII...

Page 10: ......

Page 11: ......

Page 12: ...D203082 10 08082016 2016 MIMAKI ENGINEERING CO LTD All rights reserved IG YM...

Reviews: