2
Clean the wiper.
• Include F-200 / LF-200 maintenance liquid in the clean stick and clean.
• Wipe off F-200 / LF-200 maintenance liquid so that no maintenance liquid remains.
• Refer to the Operation Manual, “Chapter 8 (2) Capping Station” steps 2 to 3 and perform the operation.
3
Clean the cap rubber of the PR-200 head.
4
Fill the cap of PR-200 head completely with the
PR-200 maintenance liquid (C-ML013-Z-B2-1-
KW).
• Fill up the PR-200 maintenance liquid just before it
overflows from the cap.
5
Close the ma intenance cover, and press the
key.
6
Set the time to one minute for the maintenance liquid to be left as it is and press the
key.
• The nozzle washing is started.
7
After washing the nozzles, perform the head cleaning (hard) for the PR-200 head.
8
Check the nozzle status with a test print.
Use the F-200 / LF-200 maintenance liquid always to
clean the wiper, bracket, and cap rubber, and do not use
the PR-200 maintenance liquid (C-ML013-Z-B2-1-KW).
To prevent nozzle clogging, do not use PR-200 mainte-
nance liquid other than the cap of the PR-200 head.