© 2011 MIMAKI ENGINEERING CO.,LTD.
5.1.6
P.1
R.1.0
5.1.6 [MOTOR TEST] X SERVO MOTOR
Function
Operation test of X-axis motor is executed.
Operation Procedures
Step
Item
Description
Remarks
1
Speed designation
[
], [
] : Selects speed.
Set value: 1 – 500 mm/s (unit: 1 mm/s)
[
], [
]:
Selection of item 2 – 4
2
Acceleration designation
[
], [
] : Selects acceleration.
Set value: 0.01 – 2.00 G (unit: 0.01 G)
3
Moving amount designation [
], [
] : Selects moving amount.
Set value: 1 mm – paper length (width) (unit: 1 mm)
When media is not detected: 1 mm-500000 mm
4
Test start
[ENTER]: Repeats reciprocating motion in the X direction
with designated conditions.
5
End
[END] : Returns to the motion starting position and executes
capping to end the test.
MAINTENANCE MANUAL > Test Items > Test Function > [MOTOR TEST] X SERVO MOTOR
Model
TS34-1800A
Issued 2011.10.17 Revised
F/W ver
1.20
Remark
1.0