MAINTENANCE MANUAL > Workflow > Electrical Parts > Replacement of the Central-IO PCB assy.
Model
SWJ-320S
Issued 2012.07.19 Revised
F/W ver
Remark
1.0
3.3.5 Replacement of the Central-IO PCB assy.
List of replacement procedures
*1 : If the SUB power switch is pressed, input the system parameter INIT= “ 1 ”, and then download the parameters uploaded in the
procedure “ 1 ” after all parameters are initialized. (The procedure “ 6 ” is not required.)
After turning off the sub and main power switches, unplug the power cord. Make sure to take 15
minutes before restarting the operation. It is very dangerous if sleep mode functions mistakenly
during the operation.
Moreover, the PCB may be damaged in case electric charge still remains inside.
Also, there is a possibility of electric shock because of high power voltage applied to the high-pres-
sure part of the DC power supply unit. Take care to avoid contact with it.
Item
Work operation
Description
Ref.
Advance
preparation
1.
Parameter upload
Before the printed-circuit board is replaced, upload its
parameter to the PC.
---
Power OFF
2.
Power OFF
Power cable removing from main body
Turing the main power OFF, and then removing the power
cable from the main body.
---
PCB replacement
3.
Central-IO PCB assy. replacement
Machine
start-up
4.
Connecting the power cable
Connecting the power cable to the main body.
---
5.
Starting up in the system parame-
ter input mode.
Turning the power switch ON, and starting up in the system
parameter mode by pressing both of [END] key and
[ENTER] key during the version display.
---
Parameter
reflection
6.
Setting the parameters to the cen-
tral-IO PCB.
Inputting the system parameter INIT= “ 10 ”.
Transferring the value of back-up data on the main PCB to
the parameter of the central-IO.
---
At starting of the machine, if the machine was started in other than the system parameter input
mode, turn off the main power once, and then re-start the machine in the system parameter mode.
At that time, be sure not to turn off the power with the SUB power switch*1 on the operation
panel. Also, do not change the parameters. (The back-up data on the main PCB will be rewritten
and not return to the original.)
Be sure to carry out the above parameters download in order to reflect the important parameters.
If this work is not carried out, the machine may not work properly.
Central-IO PCB assy.