25
Replacing the flushing tray ink absorber
7.
Remove the F-cover upward from the
flushing tray.
8.
Remove the ink absober.
9.
Place a new ink absorber (supplied) on the
tray.
Place the ink absorber (as folded) at the center.
• Make certain the ink absorber is
placed flat and touching the tray.
Otherwise, it may interfere with the
head nozzles.
10.
Place the F-cover from above.
• Place the F-cover all the way down. A
floating cover may cause trouble.
11.
Close the station cover, then press the
[ENTER] key.
The initial operation is performed.
12.
Return to the LOCAL mode.
<< LOCAL >>
X =1010
Y = 1860
Ink absorber
Carriage Out
Completed
: ent
F-cover upward