6.4.5
P.1
R.1.0
Maintenance Manual > Disassembly and Reassembly > Drive System > Linear Encoder Scale
Model CJV30/TPC Issued 2008.08.04 Revised
F/W ver. 1.00 Remark
1.0
6.4.5 Linear Encoder Scale
Work procedures
1. Remove the following covers.
• CY Cover F
• Head Cover
2. Remove the
Encoder PCB Assy
.
3. Remove the screws from the right end of the linear encoder
scale, and detach the
linear encoder scale
.
4. Remove the screw from the left end of the linear encoder scale,
and detach the
linear encoder scale
together with the springs.
5. Remove the
scale hook
and
scale holder R
from the linear
encoder scale.
Be sure to turn off the main circuit breaker to prevent unexpected movements of the printer.
While at work, be sure not to attach fingerprints or oil to the linear encoder scale. Also, pay attention not
to break or scratch it. (If contaminated, clean the scale with a neutral detergent.)
Linear Encoder Scale
Linear Encoder Scale
Scale Holder R
Linear Encoder Scale
Scale SP
Scale Holder L
Scale Hook