© 2009 MIMAKI ENGINEERING CO.,LTD.
5.1.5
P.1
R.1.2
Maintenance Manual > Test Items > Test Function > [MOTOR TEST] X SERVO MOTOR
Model CJV30/TPC Issued 2008.08.04 Revised 2009.06.30 F/W ver. 1.20 Remark
1.2
5.1.5 [MOTOR TEST] X SERVO MOTOR
Function
Operation test of X-axis motor is executed.
Operation Procedures
Step
Item
Description
Remarks
1
Speed designation
[
], [
]: Selects speed.
Set value: 1 – 500 mm/s (unit: 1 mm/s)
[
], [
]:
Selection of item 2 – 4
2
Acceleration designation
[
], [
]: Selects acceleration.
Set value: 0.01 – 2.00 G (unit: 0.01 G)
3
Moving amount designation [
], [
]: Selects moving amount.
Set value: 1 mm – media length (width) (unit: 1 mm)
When media is not detected: 1 mm – Mechanical
limit size
4
Test start
[ENTER]: Repeats reciprocating motion in the X direction
with designated conditions.
5
End
[END]: Returns to the motion starting position and
executes capping to end the test.
During the test, heater temperature control is allowed. (When [HEATER] key is effective)