background image

Specifications

IR Temperature range: 

   

For 2268-

4

0:

 -30°C to 550°C (-22°F to 1022°F) 

 

IR Accuracy:

 

     

For 2268-

4

0:

    -

30°C to -18°C (-22°F to 0°F): ±2.0°C (4°F) + 0.1°C / 1°C

 

-18°C to 10°C (0°F to 50°F): ±2.5°C (5°F)    

   10°C to 550°C (50°F to 1022°F): ±1.8°C (4°F) or 1.8%
  

 

of reading, whichever is greater   

 

*Assume ambient operating temperature of 23°C ±2°C

  

 

(70°F to 77°F)

Repeatability: 

±0.8% OR ±1°C (±2°F)  

                        (whichever is greater)

Temperature display resolution:  

 

0.1°C/°F in Primary and Secondary

Distance to spot (90% energy):

 

For 2268-

4

0: 

12 to 1

Emissivity:

 0.95

Response time:

<500 msec

Spectral response: 

8 to 14µm

Drop: 

2 meters

Laser Type:

 Class II

Max Power: 

<1mW

Wavelength: 

630-670 nm

Operating temperature: 

0°c to 50°C (32°F to 122°F)

Storage temperature: 

-20°C to 60°C (-4°F to 140°F) 

                                      without battery

Relative humidity: 

10 to 85% at 25°C, decreasing  

                                linearly to 10 to 45% at 50°C

Voltage:

 9 DC (one (1) 9V battery)

Battery life: 

Greater than 12 hrs with all functions

NOTE:

 

   The product

  may  not  meet  its  stated  

accuracy when exposed to 80-500MHz at 3V/m.

ASSEMBLY

Loading/Changing the Battery

1. Using a flat screwdriver, 

rotate the battery door 

lock to the unlocked 

position and open the 

battery door. 

2. Connect  one  (1)  9V 

battery to the connector 

block. Fit the battery 

into the compartment.

3.  Close the battery door. 

Turn the battery door 

lock to the locked position.

Selecting Celsius or Fahrenheit

To set the temperature scale, pull the trigger and 

then press the SET button three times. Press the 

buttons above the up and down arrows to toggle 

between °C and °F. Wait 5 seconds for the setting 

to save and exit.  

Setting the Laser Lock

To turn the laser on and off, pull the trigger and 

then press the SET button four times. Press the 

buttons above the up and down arrows to toggle 

between ON and OFF. Wait 5 seconds for the set-

ting to save and exit.  

SYMBOLOGY

Volts

Direct Current

CAUTION    Laser  Light  -  Do  Not 

Stare Into Beam
Laser product 

Avoid Exposure: Laser Radiation Is 

Emitted From This Aperture
To reduce the risk of injury, user must 

read operator’s manual.

FUNCTIONAL DESCRIPTION 

4

5

     1. Laser window

  

     

2. 2268-40 nameplate

       

 3. Trigger

        4. Display

      5. Mode/Set/Alarm Buttons

    6. Battery door lock

      7. Battery door

       8. Battery indicator

         9. Hold indicator

        10. Laser active indicator

         11. Trigger lock indicator

          12. Alarm indicator

          13. °C or °F indicator

          14. Primary measurement

      15. Secondary measurement

16. Mode indicator

9

10

11

14

15

16

12

8

13

3

7

6

1

2

2268-40

G87A9 SSSSSS MJJJJ

9 V

            Techtronic Industries Pty. Ltd. Rowville, Australia, 3178

Techtronic Industries (NZ) Pty. Mangere, Auckland, New Zealand, 2022