Milwaukee sds 5363-21 Operator'S Manual Download Page 3

4

5

SPECIFIC SAFETY RULES

• Wear ear protectors. 

Exposure to noise can 

cause hearing loss.

• Use auxiliary handle(s), if supplied with the 

tool. 

Loss of control can cause personal injury.

• Hold power tools by insulated gripping surfaces, 

when performing an operation where the cutting 
tool may contact hidden wiring or its own cord. 

Cutting accessory contacting a live wire may make 
exposed metal parts of the power tool live and could 
give the operator an electric shock.

• Keep hands away from all cutting edges and 

moving parts.

• Maintain labels and nameplates.

  These carry 

important information.  If unreadable or missing, 
contact a 

MILWAUKEE

 service facility for a free 

replacement.

• WARNING: 

Some dust created by power sanding, 

sawing, grinding, drilling, and other construction 
activities contains chemicals known to cause 
cancer, birth defects or other reproductive harm. 
Some examples of these chemicals are:

• lead from lead-based paint
• crystalline silica from bricks and cement and other 

masonry products, and

• arsenic and chromium from chemically-treated 

lumber.

 Your risk from these exposures varies, depending 

on how often you do this type of work. To reduce 
your exposure to these chemicals: work in a well 
ventilated area, and work with approved safety 
equipment, such as those dust masks that are spe-
cially designed to fi lter out microscopic particles.

Fig. B

Fig. C

Fig. A

GROUNDING

WARNING

 Improperly connecting the

 

 grounding wire can result in the risk of 

electric shock. Check with a qualifi ed electri-
cian if you are in doubt as to whether the 
outlet is properly grounded. Do not modify 
the plug provided with the tool. Never remove 
the grounding prong from the plug. Do not 
use the tool if the cord or plug is damaged. If 
damaged, have it repaired by a MILWAUKEE 
service facility before use. If the plug will not 
fi t the outlet, have a proper outlet installed by 
a qualifi ed electrician.

Grounded Tools: Tools with Three Prong Plugs

Tools marked “Grounding Required” have a three 
wire cord and three prong grounding plug. The 
plug must be connected to a properly grounded 
outlet (See Figure A). If the tool should electrically 
malfunction or break down, grounding provides a 
low resistance path to carry electricity away from 
the user, reducing the risk of electric shock.
The grounding prong in the plug is connected 
through the green wire inside the cord to the 
grounding system in the tool. The green wire in the 
cord must be the only wire connected to the tool's 
grounding system and must never be attached to 
an electrically “live” terminal.
Your tool must be plugged into an ap-
propriate outlet, properly installed and 
grounded in accordance with all codes 
and ordinances. The plug and outlet 
should look like those in Figure A.

Double Insulated Tools: Tools with Two Prong 
Plugs

Tools marked “Double Insulated” do not require 
grounding. They have a special double insula-
tion system which satisfi es OSHA requirements 
and complies with the applicable standards of 
Underwriters Laboratories, Inc., the 
Canadian Standard Association and 
the National Electrical Code. Double 
Insulated tools may be used in either 
of the 120 volt outlets shown in 
Figures B and C.

FUNCTIONAL DESCRIPTION

Grounded tools require a three wire extension 
cord. Double insulated tools can use either a two 
or three wire extension cord. As the distance from 
the supply outlet increases, you must use a heavier 
gauge extension cord. Using extension cords with 
inadequately sized wire causes a serious drop in 
voltage, resulting in loss of power and possible tool 
damage. Refer to the table shown to determine the 
required minimum wire size.
The smaller the gauge number of the wire, the 
greater the capacity of the cord. For example, a 14 
gauge cord can carry a higher current than a 16 
gauge cord. When using more than one extension 
cord to make up the total length, be sure each cord 
contains at least the minimum wire size required. If 
you are using one extension cord for more than one 
tool, add the nameplate amperes and use the sum 
to determine the required minimum wire size.

Guidelines for Using Extension Cords

• If you are using an extension cord outdoors, 

be sure it is marked with the suffi x “W-A” (“W” 
in Canada) to indicate that it is acceptable for 
outdoor use.

• Be sure your extension cord is properly wired 

and in good electrical condition. Always replace 
a damaged extension cord or have it repaired by 
a qualifi ed person before using it.

• Protect your extension cords from sharp objects, 

excessive heat and damp or wet areas.

READ AND SAVE ALL 

INSTRUCTIONS FOR FUTURE USE.

Recommended Minimum Wire Gauge 

for Extension Cords*

Extension Cord Length

* Based on limiting the line voltage drop to fi ve volts 

at 150% of the rated amperes.

Nameplate

Amperes

0 - 2.0

2.1 - 3.4
3.5 - 5.0
5.1 - 7.0

7.1 - 12.0

12.1 - 16.0
16.1 - 20.0

25'

18
18
18
18
16
14
12

75'

18
18
16
14
12
10

100'

18
16
14
12
10

150'

16
14
12
12

50'

18
18
18
16
14
12
10

EXTENSION CORDS

SPECIFICATIONS

Tool

Capacities

Cat. No.

Volts

AC

A

No 

Load 

RPM

No Load 

BPM

Drill Only

Rotary Hammer

Twist 

Drill Bit 

(Steel)

Twist 

Drill Bit 

(Wood)

Carbide Tipped 

Percussion Bit 

(concrete)

Thin Wall 

Core Bit

(concrete)

Thin Wall 

Core Bit

(brick/block)

5363-21

120

7

0-1400

0-5980

1/2"

1-1/4"

1"

2-1/2"

2-5/8"

SYMBOLOGY

Double Insulated

Volts Alternating Current

Amps

No Load Revolutions per Minute 
(RPM)

BPM

Blows per Minute (BPM)

Mexican Approvals Marking

Underwriters Laboratories, Inc.
United States and Canada

1. Side handle
2. Clamp
3. Depth gauge rod
4. SDS Plus bit holder
5. Trigger
6. Forward/Reverse Control
7. Mode selector lever switch

2

1

3

5

4

6

7

Summary of Contents for sds 5363-21

Page 1: ...RISQUE DE BLESSURES L UTILISATEUR DOIT LIRE ET BIEN COMPRENDRE LE MANUEL DE L UTILISATEUR PARA REDUCIR EL RIESGO DE LESIONES EL USUARIO DEBE LEER Y ENTENDER EL MANUAL DEL OPERADOR OPERATOR S MANUAL MA...

Page 2: ...eference The term power tool in the warnings refers to your mains operated corded power tool or battery operated cordless power tool POWER TOOL USE AND CARE Do not force the power tool Use the correct...

Page 3: ...The plug and outlet should look like those in Figure A Double Insulated Tools Tools with Two Prong Plugs Tools marked Double Insulated do not require grounding They have a special double insula tion...

Page 4: ...the handle firmly and pull the trigger 2 To vary the speed increase or decrease the pressure on the trigger The further the trigger is pulled the greater the speed 3 To stop the tool release the trig...

Page 5: ...lco D F Ph 01 800 832 1949 IMPORTED AND COMMERCIALIZED BY TECHTRONIC INDUSTRIES MEXICO S A DE C V Av Santa Fe 481 piso 6 Col Curz Manca CP 05349 Cuajimalpa D F LIMITED WARRANTY USA AND CANADA LIMITED...

Page 6: ...consid r e L outil lectrique adapt au projet consid r produ ira de meilleurs r sultats dans des conditions de s curit meilleures la vitesse pour laquelle il a t con u Ne pas utiliser l outil lectrique...

Page 7: ...AU BESOIN Calibres minimaux recommand s pour les cordons de rallonge Longueur du cordon de rallonge m Fiche signal tique Amp res 0 5 0 5 1 8 0 8 1 12 0 12 1 15 0 15 1 20 0 7 6 16 16 14 12 10 22 8 16 1...

Page 8: ...ur la d tente N exercez que la pression n cessaire maintenir l outil en place et emp cher la pointe du foret de patiner sur la surface Cet outil a t con u de fa on fournir le meilleur rendement pressi...

Page 9: ...gr Si le bon de commande n a pas t estampill veuillez fournir la preuve d achat d origine au centre de r parations agr Pour un entretien des pi ces des accessoires ou d autres composants composer sans...

Page 10: ...iar la corriente el ctrica de la trayectoria del usuario reduciendo de este modo el riesgo de descarga el ctrica La clavija de conexi n de puesta a tierra en el enchufe est conectada al sistema de con...

Page 11: ...ra taladrar orifi cios de mayor tama o para conductos y tuber as Los tr panos para paredes delgadas para servicio pesado de MILWAUKEE est n construidos de cuerpos de acero termotratado con puntas de c...

Page 12: ...ellada por el establecimiento donde realiz la compra Ah se reem plazar cualquier pieza o componente defectuoso sin cargo alguno para el usuario final La empresa se hace responsable de los gastos de tr...

Page 13: ...6 30 PM Central Time or visit our website at www milwaukeetool com Additionally we have a nationwide network of authorized Distributors ready to assist you with your tool and accessory needs Check yo...

Reviews: