TECHNICAL DATA 

M18 FOPH

No-load speed 

 / 

0–6860/0–8680 min

-1

Battery voltage

18 V

Weight according EPTA-Procedure 01/2014 (9.0 Ah)

4.1 kg

Recommended ambient operating temperature

-18 +50 °C

Recommended battery types

M18B, M18HB

Recommended charger

M12-18C, M12-18AC, M12-18FC

For technical data and list of powerbases that can be used for a particular application head, refer to the operating instructions of 
the application head.

 WARNING! Read all safety warnings, instructions, 

illustrations and speci

fi

cations provided with this product. 

Failure to follow all instructions listed below may result in 
electric shock, 

fi

re and/or serious injury.

Save all warnings and instructions for future reference.

 SAFETY INSTRUCTIONS

Wear ear protectors. 

Exposure to noise can cause hearing loss.

Hold the product by insulated gripping surfaces when 
performing an operation where the cutting tool may contact 
hidden wiring. 

Contact with a "live" wire will also make exposed 

metal parts of the product "live" and could give the operator an 
electric shock.

ADDITIONAL SAFETY AND WORKING INSTRUCTIONS

Always wear goggles when using the product. Wear gloves, 
sturdy non-slipping shoes, and apron.
Remove the battery pack before starting any work on the 
product.
Do not dispose of used battery packs in the household refuse 
or by burning them. MILWAUKEE distributors accept old 
batteries to protect our environment.
Do not store the battery pack together with metal objects (short 
circuit risk).
Use only M18 System chargers for charging M18 System 
battery packs. Do not use battery packs from other systems. 
Never break open battery packs and chargers, and store them 
only in dry rooms. Keep battery packs and chargers dry at all 
times.
Battery acid may leak from damaged batteries under extreme 
load or extreme temperatures. In case of contact with battery 
acid, wash it off immediately with soap and water. In case 
of eye contact, rinse thoroughly for at least 10 minutes and 
immediately seek medical attention.

ADDITIONAL BATTERY SAFETY WARNINGS

 WARNING!

 To reduce the risk of 

fi

 re, personal injury, and 

product damage due to a short circuit, never immerse your 
tool, battery pack, or charger in 

fl

 uid or allow a 

fl

 uid  to 

fl

 ow 

inside them. Corrosive or conductive 

fl

 uids, such as seawater, 

certain industrial chemicals, and bleach or bleach-containing 
products, etc., can cause a short circuit.

SPECIFIED CONDITIONS OF USE

This powerbase is designed to drive approved application 
heads of the MILWAUKEE brand.

Do not use this product in any other way as stated for normal 
use.

BATTERIES

Battery packs that have not been used for some time should be 
recharged before use.
Temperatures in excess of 50°C (122°F) reduce the 
performance of the battery pack. Avoid extended exposure to 
heat or sunshine (risk of overheating).
The contacts of chargers and battery packs must be kept clean.
For an optimum lifetime, the battery packs have to be fully 
charged after use.
To obtain the longest possible battery life, remove the battery 
pack from the charger once it is fully charged.
For battery pack storage longer than 30 days:

 

Store the battery pack where the temperature is below 
27°C and away from moisture.

 

Store the battery packs in a 30% - 50% charged condition.

 

Every six months of storage, charge the pack as normal.

BATTERY PACK PROTECTION

The battery pack has an overload protection that protects it 
from being overloaded and helps to ensure long life.
Under extreme stress, the battery electronics turn off the 
product automatically. To restart, turn the product off and then 
on again. If the product does not start up again, the battery 
pack may have discharged completely. In this case, it must be 
recharged in the battery charger.

TRANSPORTING LITHIUM BATTERIES

Lithium-ion batteries are subject to the Dangerous Goods 
Legislation requirements.
Transportation of lithium-ion batteries has to be done in 
accordance with local, national, and international provisions 
and regulations.

 

The user can transport the batteries by road without further 
requirements.

 

Commercial transport of lithium-ion batteries by third parties 
is subject to Dangerous Goods regulations. Transport 
preparation and transport are exclusively to be carried out 
by appropriately trained persons and the process has to be 
accompanied by corresponding experts.

When transporting batteries:

 

Ensure that battery contact terminals are protected and 

Summary of Contents for M18 FOPH-0

Page 1: ...M18 FOPH 0...

Page 2: ...TA M18 FOPH EA The overview shows a selection of different application heads to this MILWAUKEE powerbase MILWAUKEE MILWAUKEE MILWAUKEE Ikhtisar gambar menampilkan pilihan berbagai head perangkat yang...

Page 3: ...3 M18 FOPH EXA M18 FOPH EXA M18 FOPH 0 max 1 x max 1 x...

Page 4: ...4 click 1 2 Remove the battery pack before starting any work on the product Lepaskan paket baterai sebelum memulai pekerjaan apa pun pada produk...

Page 5: ...5 2 1...

Page 6: ...6 1 2 2x Place Handle Here...

Page 7: ...7 1 2 3 click 1 2 1...

Page 8: ...8 1 1 2 2 click The powerbase may be operated only with a mounted application head Powerbase hanya dapat dioperasikan dengan sebuah head perangkat terpasang...

Page 9: ...START STOP 1 2 3 9 Handle insulated gripping surface Gagang permukaan genggam berinsulasi...

Page 10: ...10...

Page 11: ...ct damage due to a short circuit never immerse your tool battery pack or charger in fluid or allow a fluid to flow inside them Corrosive or conductive fluids such as seawater certain industrial chemic...

Page 12: ...and order the drawing at your local service centre SYMBOLS CAUTION WARNING DANGER Remove the battery pack before starting any work on the machine Read the instructions carefully before starting the m...

Page 13: ...13 13 M18 FOPH 0 6860 0 8680 min 1 18 V EPTA Procedure 01 2014 9 0 Ah 4 1 kg 18 50 C M18B M18HB M12 18C M12 18AC M12 18FC MILWAUKEE M18 M18 10 MILWAUKEE 50 C 122 F 30 27 C 30 50 MILWAUKEE MILWAUKEE...

Page 14: ...14 n0 V...

Page 15: ...15 15 M18 FOPH 0 6860 0 8680 min 1 18 V EPTA Procedure 01 2014 9 0 Ah 4 1 kg 18 50 C M18B M18HB M12 18C M12 18AC M12 18FC M18 M18 10 50 C 122 F 30 27 C 30 50 6...

Page 16: ...16 16 n0 V...

Page 17: ...17 17 M18 FOPH 0 6860 0 8680 min 1 18 V EPTA 01 2014 9 0 Ah 4 1 kg 18 50 C M18B M18HB M12 18C M12 18AC M12 18FC System M18 System M18 10 MILWAUKEE 50 C 122 F 30 27 C 30 50 6 3...

Page 18: ...18 18 MILWAUKEE MILWAUKEE n0 V...

Page 19: ...19 19 M18 FOPH 0 6860 0 8680 min 1 18 V EPTA 01 2014 9 0 Ah 4 1 kg 18 50 C M18B M18HB M12 18C M12 18AC M12 18FC MILWAUKEE System M18 System M18 10 MILWAUKEE 50 C 122 F 30 27 C 30 50...

Page 20: ...20 20 MILWAUKEE MILWAUKEE n0 V...

Page 21: ...rai yang rusak akibat beban atau suhu yang ekstrem Jika asam baterai mengenai Anda segera cuci dengan sabun dan air Jika mengenai mata bilas sebanyak banyaknya selama setidaknya 10 menit dan segera da...

Page 22: ...anti hubungi salah satu dari pusat layanan MILWAUKEE kami lihat daftar alamat layanan garansi kami Jika diperlukan gambar pecahan komponen dapat dipesan Sebutkan tipe mesin dan sepuluh digit nomor yan...

Page 23: ......

Page 24: ...961013368 01A...

Reviews: