ASSEMBLY
WARNING
To reduce the risk of in-
jury, always remove the battery pack before
removing the dust box. Do not use tool with-
out dust box and HEPA
fi
lter in place.
CAUTION
Keep
fi
lter clean. Ef
fi
ciency of
the HAMMERVAC™ is largely dependent on
the
fi
lter. A dirty
fi
lter will reduce the air
fl
ow
and overall ef
fi
ciency of the system. Do not
clean with water or compressed air. Remove
from dust box and tap clean.
Installing/Removing the
Dust Box and HEPA Filter
To
remove
the dust box:
1. Turn OFF the tool.
2. Remove the battery pack.
3. Press in the dust box buttons and pull the dust
box away from the HAMMERVAC™.
4. Empty dust from the dust box.
5. If necessary, pull the HEPA
fi
lter away from the
dust box and tap clean. Do not clean with water
or compressed air. After about 1500 holes or loss
of suction, discard and replace HEPA
fi
lter.
To
install
the dust box:
1. Slide the dust box into the body of the HAM-
MERVAC™.
2. The dust box latches should snap into place.
NOTE:
Do not operate the HAMMERVAC™ with-
out the dust box and HEPA
fi
lter in place. Dust box
cannot be installed without HEPA
fi
lter.
Adjusting/Installing/Removing Nozzle
Replace the nozzle:
•
After drilling about 1500 holes,
•
When the bit brush shows signs
of wear,
•
When suction is reduced,
•
When dust escapes through the
bit brush during use
Attaching the HAMMERVAC™ to the Rotary
Hammer
These HAMMERVAC™ Dust Extractors are for
use with dedicated rotary hammers. Refer to the
Speci
fi
cations chart for compatible tools.
1. Remove the battery pack from the rotary ham-
mer.
Correct
Incorrect
Incorrect
Drill Depth
M28
M18
Cat. No.
M18-28CPDEX-0
2. Slide the foot of the rotary hammer onto the
dust extractor.
3. Push the contacts through the protective cover
on the rotary hammer. The hammer release will
snap into place.
Installing/Removing the Bit
Fitting the HAMMERVAC™ to the Tool and Bit
For proper suction and depth
control, position the nozzle as-
sembly so the bit is
fl
ush with the
forward face of the nozzle:
1. Press and hold the tool and
bit adjustment button.
2. Push in the nozzle assembly
until the bit is
fl
ush with the
front face of the nozzle.
3. Release the tool and bit ad-
justment button.
NOTE:
Fully extend the HAM-
MERVAC™ before storing to
preserve spring life.
Setting the Drilling Depth
1. Fit the HAMMERVAC™ to the Tool and Bit.
2. Press and hold the depth gauge button and
slide the depth gauge to the desired depth. The
drilling depth is the last visible measurement
shown when viewed from the top of the tool.
To ensure the HAMMERVAC™ is properly set
to the tool, bit, and desired depth, always drill
a test hole.
The M18-28CPDEX-0 must be
properly adjusted for use with
the M18CHP-0 M18
TM
FUEL
TM
28mm Rotary Hammer. Press in
the nozzle adjustment button
and slide to the appropriate
detent.
To replace the nozzle, press in the nozzle adjust-
ment button and pull out from the lower nozzle
assembly. Slide the new nozzle into the lower
nozzle assembly until it snaps into place.
Installing/Removing the Bit Slide the bit through
the nozzle and then install into the tool according
to the tool manufacturer's instructions. For best