background image

5

Measuring

Milwaukee LM 60

GB

D

F

I

E

P

NL

DK

NO

S

FIN

GR

TR

CZ

SK

PL

HU

SLO

HR

LV

LT

ET

RU
BG

RO

MK

CN

Reference Setting

Default reference setting is from the rear of the 
instrument.

The instrument can be set for the following measure-

ments:

To measure from an edge (see drawing 

), fold 

out the stop bracket until it snaps in for the first 
time. See drawing 

.

To measure out of a corner (see drawing 

), 

fold out the stop bracket until it snaps in, push 
the stop bracket with a little force to the right 
side; the stop bracket can now be completely 
unfolded. See drawing 

.

CAUTION:

Make sure that when measuring from the 

unfolded endpiece, the measuring reference is set to 
"End piece"!

1x briefly: the next measurement is taken from 
the front edge.

2x briefly: the measurement is taken from the 
unfolded end piece.

After one measurement, the reference returns auto-
matically to the default setting (rear reference).

1x long: the measurements are taken with the 
front as reference until a new measuring refer-
ence is set

2x long: the measurements are taken from the 
unfolded end piece until a new measuring refer-
ence is set.

See drawing 

.

Measuring

Single Distance Measurement

1x briefly: the laser is activated.

1x briefly: a distance measurement is taken. 

The result is displayed immediately.

Continuous measurement

Distances can be measured with this function

1x long: a "beep" is sounded.A continuous 
measurement is started.

1x briefly: the continuous measurement is 
stopped. 

The last measured value is displayed in the summary 
line.

Minimum-/Maximum-Measuring

This function enables determining the minimum or 
maximum distance from a specific measuring point, 
e.g. the determination of room diagonals (maximum 
value) or horizontal distance (minimum value).

Summary of Contents for LM 60

Page 1: ...GH XVR QVWUXo HV GH VHUYLoR HEUXLNVDDQZLM LQJ UXJVDQYLVQLQJ UXNVDQYLVQLQJ l WW RKMH XOODQ P N ODYX X 1iYRG N SRX tYiQt 1iYRG QD SRX tYDQLH QVWUXNFMD REV XJL H HOpVL WPXWDWy 1DYRGLOR D XSRUDER 8SXWH R...

Page 2: ......

Page 3: ......

Page 4: ......

Page 5: ...Gebruiksaanwijzing Brugervejledning Brukerh ndbok Bruksanvisning K ytt j n k sikirja Kullanma K lavuzu 8 L YDW HO VN i S ru N D 1 i YRGQ DSRX L W L H Q VW U X N FM DREV X JL DV Q i O DW L W P X W DW...

Page 6: ...GB D F I E P NL DK NO S FIN GR TR CZ SK PL HU SLO HR LV LT ET RU BG RO MK CN...

Page 7: ...finan cial and environmental damage Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner Intended Use Permitted...

Page 8: ...harge of the instrument WARNING The person responsible for the instrument must ensure that the equipment is used in accord ance with the instructions This person is also accountable for the deployment...

Page 9: ...sed for a long time remove the batteries as a protection against corrosion Operation Measuring Conditions Range Range is limited to 60 m At night or dusk and if the target is in shadow the measuring r...

Page 10: ...ay that in case of an erroneous measurement malfunction of the device or power failure due to installed safety measures e g safety limit switch it is assured that no damage will occur Switching on off...

Page 11: ...is taken from the unfolded end piece After one measurement the reference returns auto matically to the default setting rear reference 1x long the measurements are taken with the front as reference unt...

Page 12: ...urement e g length 1x briefly takes second distance measurement e g width The result of the area measurement is displayed in the summary row the individually measured values are displayed in intermedi...

Page 13: ...e sure that the first measurement and the distance to be measured are at right angles Use the minimum maximum function Indirect measurement determining a distance using 2 auxilliary measurements See d...

Page 14: ...take out point is displayed When approaching a stakeout point to less than 0 10 m the instrument starts to beep When the point is reached the beep sound changes and inter mediate line 1 starts to flas...

Page 15: ...e too low Warm device up 255 Received signal too weak time for a measurement too long Use a target plate 256 Received signal too strong Use target plate gray side 257 Faulty measure ment too much back...

Page 16: ...relevant standards and regulations Yet the possibility of the product causing interfer ence in other equipment cannot be fully excluded Laser classification The Milwaukee LM 60 produces a visible las...

Page 17: ...ent and take them to the collection points provided in accordance with national or local regulations The product must not be disposed with household waste Dispose of the product appropriately in accor...

Reviews: