STARTUP PROTECTION

A zero-voltage switch prevents the machine from restarting 

after a power failure. On resuming work, switch the 

machine off  and then back on again.

STARTING CURRENT L SMOOTH START

The starting current for the machine is several times 

greater than rated current. The starting current limiter 

reduces the starting current to such an extent that a fuse 

(16 A, slow-blow) is not tripped.
Electronic smooth start for save use prevents jerky run-up 

of the machine.

ELECTRONICS

The speed of rotation is adjusted electronically when the 

load increases.
In case of a longer overload period the speed is decreased 

electronically. The machine continues to run slowly to cool 

down the motor coil. After switching off  and on the machine 

can be used at rated load.

MAINS CONNECTION

Connect only to single-phase a.c. current and only to the 

system voltage indicated on the rating plate. It is also 

possible to connect to sockets without an earthing contact 

as the design conforms to safety class 

II

.

MAINTENANCE

If the supply cord of this power tool is damaged, it must be 

replaced by a specially prepared cord available through the 

service organization
The ventilation slots of the machine must be kept clear at 

all times.
Use only Milwaukee accessories and spare parts. Should 

components need to be exchanged which have not been 

described, please contact one of our Milwaukee service 

agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. 

Please state the machine type printed as well as the 

six-digit No. on the label and order the drawing at your 

local service agents or directly at: Techtronic Industries 

GmbH, Max-Eyth-Straße 10, 71364 Winnenden, Germany.

SYMBOLS

CAUTION! WARNING! DANGER!

Always disconnect the plug from the socket 

before carrying out any work on the machine.

Please read the instructions carefully before 

starting the machine.

Always wear goggles when using the 

machine.

Wear gloves!

Do not use force.

Accessory - Not included in standard 

equipment, available as an accessory.

Do not dispose of electric tools together with 

household waste material.

Electric tools and electronic equipment that 

have reached the end of their life must be 

collected separately and returned to an 

environmentally compatible recycling facility.

Check with your local authority or retailer for 

recycling advice and collection point.

Class II tool, tool in which protection against 

electric shock does not rely on basic 

insulation only, but in which additional safety 

precautions, such as double insulation or 

reinforced insulation, are provided. 

There being no provision for protective 

earthing or reliance upon installation 

conditions.

European Conformity Mark

British Confomity Mark

Regulatory Compliance Mark (RCM). Product 

meets applicable regulatory requirements.

Ukraine Conformity Mark

EurAsian Conformity Mark

Summary of Contents for HEAVY DUTY AP 14-2 200E

Page 1: ...AP 14 2 200E Original instructions ...

Page 2: ... and functional description Text section with Technical Data important Safety and Working Hints and description of Symbols 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 16 19 22 25 28 31 34 37 40 43 46 49 52 55 58 61 64 67 70 73 46 79 82 85 88 91 94 99 ...

Page 3: ...4 5 14 12 9 10 6 7 8 ...

Page 4: ...6 7 2 1 3 1 2 1 2 ...

Page 5: ...8 9 A G ...

Page 6: ...10 11 START STOP STOP 1 1 2 2 STOP START LOCK ...

Page 7: ...12 13 ...

Page 8: ...14 15 6 7 5 8 SERVICE 1 2 4 3 ...

Page 9: ...power tool down until the accessory has come to a complete stop The spinning accessory may grab the surface and pull the power tool out of your control m Do not run the power tool while carrying it at your side Accidental contact with the spinning accessory could snag your clothing pulling the accessory into your body n Regularly clean the power tool s air vents The motor s fan will draw the dust ...

Page 10: ... to safety class II MAINTENANCE If the supply cord of this power tool is damaged it must be replaced by a specially prepared cord available through the service organization The ventilation slots of the machine must be kept clear at all times Use only Milwaukee accessories and spare parts Should components need to be exchanged which have not been described please contact one of our Milwaukee servic...

Page 11: ...1 21 4931 4702 60 Copyright 2021 Techtronic Industries GmbH Max Eyth Str 10 71364 Winnenden Germany 49 0 7195 12 0 www milwaukeetool eu Techtronic Industries UK Ltd Fieldhouse Lane Marlow Bucks SL7 1HZ UK ...

Reviews: