background image

6

7

WARNING! Read all safety warnings and all 

instructions. 

Failure to follow the warnings and instructions 

may result in electric shock, fi re and/or serious injury. 

Save all warnings and instructions for future reference. 

SAFETY INSTRUCTIONS

Do not stare into beam. Do not point laser light at other 

persons.
Do not view directly into beam with optical instruments 

(binocular, telescope).
Do not point laser at refl ective surfaces.
Avoid exposure to laser radiation. Laser may emit 

hazardous radiation.
Avoid dangerous environments. Do not use in rain, snow, 

damp or wet locations. Do not use in the presence of 

explosive atmospheres (gaseous fumes, dust or fammable 

materials) because sparks may be generated when inserting 

or removing battery pack, possibly causing fi re.
This tool is designed to be powered by 9 V battery properly 

inserted into the Instrument. Do not attempt to use with any 

other voltage or power supply.
Do not leave batteries within the reach of children.
Do not mix new and used batteries. Do not mix brands (or 

types within brands) of batteries.
Do not mix rechargeable and non-recharge-able batteries.
Install batteries according to polarity (+ / –) diagrams.
Properly dispose of used batteries immediately.
Battery acid may leak from damaged batteries under 

extreme load or extreme temperatures. In case of contact 

with battery acid wash it off  immediately with soap and 

water. In case of eye contact rinse thoroughly for at least 10 

minutes and immediately seek medical attention.

This appliance is not intended to 

be used or cleaned by persons 

with reduced physical, sensory or 

mental capabilities, or lack of 

experience or knowledge, unless 

they have been given instructions 

concerning the safe use of the 

appliance by a person legally 

responsible for their safety. They 

should be supervised whilst using 

the appliance. Children shall not 

use, clean or play with this 

appliance, which when not in use 

should be secured out of their 

reach.

Warning! 

To reduce the risk of fi re, personal injury, and 

product damage due to a short circuit, never immerse your 

tool, battery pack or charger in fl uid or allow a fl uid to fl ow 

inside them. Corrosive or conductive fl uids, such as 

seawater, certain industrial chemicals, and bleach or bleach 

containing products, etc., can cause a short circuit.

SPECIFIED CONDITIONS OF USE

The Laser Thermometer can be used for non-contact 

temperature measurement.
Do not use this product in any other way as stated for 

normal use.

DISPLAY

Battery Indicator
Hold Indicator
Trigger Lock Indicator
Alarm indicator

°C or °F indicator
Primary measurement

Secondary measurement

Mode indicator

Alarm button
Set button
Mode button 

ENGLISH

TECHNICAL DATA 

LASER THERMOMETER 2267-40

Laser class ............................................................................ 2

Max. Power.......................................................................... <1  mW

Wavelength ................................................................. 630-670  nm

IR Temperature range .......................................... -30°C to 400  °C

IR Accuracy

  -30°C to -18°C .................................................................. ±2  °C +0.1/1 °C

   -18°C to 0°C ................................................................. ±2.5  °C

   0°C to 400°C.................................................................... ±2  °C or 2% of reading, whichever is greater

   Assume ambient operating temperature of 23°C ±2°C

Min. measuring distance...................................................... 50  mm < 50 °C, 100 mm > 50 

°C

Temperature display resolution .......................................... 0.1  °C in Primary and Secondary

Emissivity .......................................................................... 0.95

Response time................................................................. <500  msec

Spectral response......................................................... 8 to 14  μm

Distance to spot ............................................................ 10 to 1

Repeatability ..................................................................... ±0.8  % or ±1°C(whichever is greater)

Operating temperature ............................................. 0°C to 50  °C

Storage temperature.............................................. -20°C to 60  °C w/o battery

Relative humidity:  ........................................................ 10 to 85  % RH non-condensing at 25°C ambient, decreasing linearly to 10 to 45% at 50°

Voltage Battery ...................................................................... 9  V

Battery life......................................................................... > 12  h with all functions

Weight according EPTA-Procedure 01/2014 ..................... 290  g

ENGLISH

SELECTING CELSIUS OR FAHRENHEIT

To set the temperature scale, pull the trigger and then press 

the SET button three times. Press the buttons above the up 

and down arrows to toggle between °C and °F. Wait 5 

seconds for the setting to save and exit.

SETTING THE LASER LOCK

To turn the laser on and off , pull the trigger and then press 

the SET button four times. Press the buttons above the up 

and down arrows to toggle between ON and OFF. Wait 5 

seconds for the setting to save and exit.

OPERATION

Scanning Object IR Temperature

1. Pull and hold the trigger for 

at least 2 seconds and scan 

the surface temperature of an 

object. A laser pointer indicates 

the center of the circular area 

being scanned.
NOTE: The object should be 

larger than the spot being 

scanned. If not, readings will 

be aff ected. See Distance To 

Spot for necessary object size. 
2. As you continue to hold the 

trigger, the icon 

 is 

displayed along with the 

surface temperature (primary 

measurement) and maximum 

temperature (secondary 

measurement) readings. 
3. Release the trigger. HOLD 

is displayed until the screen 

shuts off  in about seven 

seconds. 
NOTE: A quick change in temperature (>10°C) aff ects the 

meter’s readings. Allow the meter to reach ambient 

temperature before use (5 to 30 minutes, depending on 

temperature change).

Temperature Alarm 

Press the ALARM button to 

turn on the alarm function. The 

bell icon is displayed. If the 

temperature reading is outside 

the preset range, the 

temperature reading will fl ash.

Setting Preset Range for the Alarm

1. To set the alarm range, pull 

the trigger and then press the 

SET button. Repeat to toggle 

between HI and LO settings.

2. Press the up or down arrow 

soft keys to toggle between 

temperatures. Wait 5 seconds 

for the ranges to save and exit.

Low Battery

When the Low Battery icon is 

displayed, change the 

batteries. 

MODE INDICATOR

MAX

Displays maximum temperature measured during 

a continuous reading

MIN

Displays minimum temperature measured during 

a continuous reading

AVG

Displays average temperature of last 20 

measurements during a continuous reading4

DIF

Displays the diff erence between MAX and MIN 

during a continuous reading

MAINTENANCE

Clean the laser windows with a soft, moist cloth to keep 

them clean and clear. Remove battery before cleaning.

Warning!

To reduce the risk of personal injury and damage, never 

immerse your tool in liquid or allow a liquid to fow inside it.
Clean dust and debris from tool. Keep tool handles clean, 

dry and free of oil or grease. Use only mild soap and a 

damp cloth to clean the tool since certain cleaning agents 

and solvents are harmful to plastics and other insulated 

parts. Never use fl ammable or combustible solvents around 

tools
Use only Milwaukee accessories and Milwaukee spare 

parts. Should components need to be replaced which have 

not been described, please contact one of our Milwaukee 

service agents (see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. 

Please state the Article No. as well as the machine type 

printed on the label and order the drawing at your local 

service agents or directly at: Techtronic Industries GmbH, 

Max-Eyth-Straße 10, 71364 Winnenden, Germany.