symbology

Underwriters Laboratories, Inc., 

United States and Canada

European Conformity Mark

Australia-New Zealand 
Certification Mark 

1

Canadian Conformity Mark

Cat III

Classification of transient 

overvoltages, based on nominal 

line voltage to earth. 

Fuse

Do not dispose of this product as 

unsorted municipal waste.

Read Operator’s Manual

Double Insulation

Risk of Electric Shock

Earth (Ground)

Danger, Warning, or Caution - 

Consult the operators manual for 

additional safety information.
Battery

Dial Position

Range

Resolution

Accuracy

 

Voltage AC

6mV-600mV/6V/

60V/600V

0.1mV/0.001V/

0.01V/0.1V

±(1.0% + 3 dgt) (45~500Hz)

±(2.0% + 3 dgt) (500~1000Hz)

 

Voltage DC

600mV/6V/

60/600V

0.1mV/0.001V/

0.01V/0.1V

±(0.5% + 2 dgt)

Hz

Hertz

2Hz-99.99Hz/999.9Hz/

9.999kHz/50kHz

0.01Hz/0.1Hz/

0.001kHz/0.01kHz

±(0.1% + 2 dgt)

Sensitivity: 10Vp-p

 

Resistance

600Ω/6kΩ/60kΩ/

600kΩ/6MΩ

0.1/0.001k/0.01k/

0.1k/0.001MΩ

±(1.0% + 5 dgt)

±(1.0% + 5 dgt)

40MΩ

0.01MΩ

±(2.0% + 5 dgt)

 

Continuity

Cont Buzzer 

0-600.0Ω

0.1 Ω

Beeper sounds at 30 Ω and below

 

Capacitance

100μF / 1000μF

0.1μF / 1μF

±(1.9% + 2 dgt)

 

Current AC

0.04A - 6A / 10A

0.001A/0.01A

±(1.5% + 3 dgt) (45~500Hz)

 

Current DC

6A/10A

0.001A/0.01A

±(1.0% + 3 dgt)

functions 

*  This is a True-RMS instrument. All AC voltage and 

AC current readings are True-RMS values.

*  Input impedance: Voltage DC: 10MΩ; Voltage AC: 

10MΩ // less than 100pF

*  Overload protection: 

  Voltage DC, Voltage AC, and Hertz: AC/DC 720V for 

10 second

     Current DC & Current AC: AC/DC 20A for 10 sec.

     Resistance, Continuity, and Capacitance: AC/

      

DC 600V for 10 second   

*  Maximum measurement time: 1 minute at 10A, rest 

time 20 minutes minimum

*  Minimum fr

e

quency measurement is 2Hz

*  Minimum AC Current measurement is 0.040A

* For AC Voltage, and AC Current:

   Additional Accuracy by Crest Factor (C.F.): 

Add

 

6.0% for C.F. 1.0 ~ 2.0

   Add 7.0% for C.F. 2.0 ~ 2.5

   Add 9.0% for C.F. 2.5 ~ 3.0

   Max. Crest Factor: 1.6 for 6600 ~ 5000 digits

   2.0 for 5000 ~ 3000 digits

   3.0 for 3000 ~ 0 digits

* Measurement accuracy of square wave and trun

-

cated waveforms at 1kHz is unspecified.

Summary of Contents for 2216-40

Page 1: ...OPERATOR S MANUAL DIgITAL MULTIMETER Cat No 2216 40 TO REDUCE THE RISK OF INJURY USER MUST READ AND UNDERSTAND OPERATOR S MANUAL ...

Page 2: ...ement Do not ground yourself while measuring Avoid body contact with earthed or grounded sur faces such as pipes radiators ranges and refrigerators This instrument is to be used only in its intended applications or conditions Otherwise the instrument s safety functions may not work resulting in serious personal injury and instru ment damage To reduce the risk of injury from shock and arc blasts al...

Page 3: ...om the battery avoid contact If contact accidentally occurs flush with water If liquid contacts eyes additionally seek medical help Liquid ejected from the battery may cause irritation or burns Accuracy is specified for 1 year after calibration at operating temperatures of 14 F to 122 F 10 C to 50 C with relative humidity less than 85 Maximum voltage between any terminal and earth ground 600 V Tem...

Page 4: ...5 dgt 1 0 5 dgt 40MΩ 0 01MΩ 2 0 5 dgt Continuity Cont Buzzer 0 600 0Ω 0 1 Ω Beeper sounds at 30 Ω and below Capacitance 100μF 1000μF 0 1μF 1μF 1 9 2 dgt Current AC 0 04A 6A 10A 0 001A 0 01A 1 5 3 dgt 45 500Hz Current DC 6A 10A 0 001A 0 01A 1 0 3 dgt functions This is a True RMS instrument All AC voltage and AC current readings are True RMS values Input impedance Voltage DC 10MΩ Voltage AC 10MΩ les...

Page 5: ...exists Do not use with the battery cover removed Keep fingers behind the guards and away from test lead tips during measurements cauTion Readings may fluctuate or be influenced in noisy environment 1 Set the dial to position 2 Connect the red test lead to the VΩ terminal and the black test lead to the COM terminal 3 Connect the test leads to the circuit under test The reading is displayed 1 Set th...

Page 6: ... red test lead to the VΩ terminal and the black test lead to the COM terminal 3 Discharge capacitor 4 Connect the test leads to both ends of the capacitor under test 5 The reading is displayed AC Current danger To reduce the risk of electric shock for Resistance Continuity and Capacitance measurements never use the Digital Multimeter on an energized circuit Make sure a capacitor is fully discharge...

Page 7: ...When you turn the Digital Multimeter on it defaults to Autorange and AUTO is displayed To enter the Manual Range mode press RANGE button AUTO disappears In the Manual Range mode press RANGE button to increment the range After the highest range the Meter wraps to the lowest range To exit Manual Range press RANGE button for two seconds or change the dial The Meter returns to Autorange and AUTO is di...

Page 8: ...NCE OF ANY DAMAGE TO FAILURE OF OR DEFECT IN ANY PRODUCT INCLUDING BUT NOT LIMITED TO ANY CLAIMS FOR LOSS OF PROFITS THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OR CONDITIONS WRITTEN OR ORAL EXPRESSED OR IMPLIED WITHOUT LIMITING THE GENERALITY OF THE FOREGOING MILWAUKEE DISCLAIMS ANY IM PLIED WARRANTY OF MERCHANTABILITY OR FITNESS FORAPARTICULAR USE OR PURPOSE AND ALL OTHER WARR...

Reviews: