5
(4) AC Current
Range Resolution
Accuracy
200.0A 0.
1A
±
(3% r 3 digits)
Frequency Response:
45 ~ 60Hz (Sine Wave)
AC Conversion Type:
AC coupled average sensing, RMS indication
Additional Accuracy by Crest Factor (C.F.):
Same as ACV.
Max. Crest Factor:
Same as ACV.
Adjacent Conductor Influence:
< 0.08A/A
Response Time of AC Input:
< 2 sec. when the LCD reading is bigger than 1000 digits in each
range.
Overload Protection:
AC 400A for 10 second.
(5) Resistance
Range Resolution
Accuracy
400.0
Ω
0.1
Ω
±
(1% r 5 digits)
4.000k
Ω
0.001k
Ω
40.00k
Ω
0.01k
Ω
400.0k
Ω
0.1k
Ω
4.000M
Ω
0.001M
Ω
±
(1% r 2 digits)
40.00M
Ω
*
0.01M
Ω
±
(2% r 5 digits)
*
There is a little rolling less then
±
50 digits when measuring > 10.00 M
Ω
.
Open Circuit Voltage:
Approx. 0.4V
Response Time:
< 1.5 sec.
Overload Protection:
AC/DC 600V for 10 second.
(6) Continuity
Range Resolution
Accuracy
400.0
Ω
0.1
Ω
±
(1% r 5 digits)
Open Circuit Voltage:
Approx. 0.4V
Continuity:
Built-in buzzer sounds when measured resistance is less than 30
Ω
and sounds off
when measured resistance is more than 200
Ω
, Between 30
Ω
to 200
Ω
the buzzer
maybe sound or off either.
Continuity Indicator:
2.7KHz Tone Buzzer
Response Time of Buzzer:
< 500
μ
sec.
Response Time of LCD reading:
< 1.5 sec.
Overload Protection:
AC/DC 600V for 10 second.