Ë
5. Output Board
—The 16 output relays are socket-mounted SPDT electromechanical relays with contacts
capable of faithfully conducting a maximum of 25VA (0.1 ampere or 100 milliamperes at 220/240VAC, or 0.2
amperes or 200 milliamperes at a maximum of 110/120VAC). The output will be either 220/240VAC or
110/120VAC depending on the machine model/type.
These outputs and their power source are intended only to drive another relay with higher contact ratings that,
in turn, may drive a pump, valve, solenoid, etc., from a separate power source. Never use these outputs to
directly drive a pump, valve, or solenoid unless the maximum current required never exceeds the above
values. Higher ampere or VA loads will burn out traces on the printed circuit board or possibly overload and
damage the control circuit transformer.
THE HARDWARE IN C4A ELECTRONIC COIN WASHER-EXTRACTOR CONTROLS
MSFD0503AE/9274AV (2 of 2)
Summary of Contents for C4A