TO TEST POWER SUPPLIES OUTPUT
1. MAKE SURE MACHINE IS ON.
2. USING HIGH QUALITY DIGITAL VOLTMETER (FLUKE MODEL
77 OR EQUAL) MEASURE THE VOLTAGE ON ANY ONE OF
BOARDS IN THE CARD CAGE *MTA#2 BETWEEN PINS 3 (+5V)
AND PIN 4 (GND). THE VOLTAGE RANGE SHOULD BE 5.01-
5.12VDC. SEE FIGURE 1.
3. MEASURE THE VOLTAGE AT BPB ON CONNECTOR J4 BETWEEN
PIN 1 (+12V) AND PIN 2 (GND). THE VOLTAGE RANGE SHOULD
BE 12.2-12.4VDC. SEE FIGURE 2
TO ADJUST POWER SUPPLY VOLTAGES
1. +5V,+12V &-12V IS PROVIDED BY PART NUMBER 08PSS3401T
LABELED ESPS. POWER SUPPLY PART NUMBER 08PSS2401T
PROVIDES THE +12V FOR THE PROCESSOR BD LABELED ESPS2.
2. LOCATE THE VOLTAGE ADJUSTMENT POTENTIOMETER. THE
POTENTIOMETER WILL BE A SMALL BLUE COMPONENT. IT IS
SOLDERED ON EACH POWER SUPPLY’S PRINTED CIRCUIT
BOARD. THERE MAY HAVE A SPOT OF SILICONE ON
ADJUSTMENT SCREW. SEE FIGURE 3.
3. USING A SMALL (POCKET TYPE) SCREW DRIVER REMOVE
THE SILICONE AND TURN THE POTENTIOMETER
TURNING CLOCKWISE TO RAISE THE VOLTAGE AND
COUNTER-CLOCKWISE TO LOWER.
4. RE-APPLY SPOT OF ELECTRONIC GRADE SILICONE ON
ADJUSTMENT SCREW TO FIX IN PLACE. RE-TEST TO
5VDC ON ESPS AND +12VDC ON ESPS2 ARE
WITHIN CORRECT VOLTAGE RANGES.
12.30
BPB
PRT
OUCHSCREEN
IN SWITCH P
ANEL
NEGATIVE
PROBE
POSITIVE
PROBE
FIG 1.
FIG 2.
RAISE
VOLTAGE
LOWER
VOLTAGE
ADJUSTMENT
PONTENTIOMETER
B2T2014012
2014243A
DC VOLTAGE
CONNECTION
FIG 3.
POWER SUPPLY
PRINTED CIRCUIT
BOARD.
INPUT
POWER
CONNECTION
IMPORTANT
SETTING MILTOUCH-EX POWER SUPPLIES
TM
5.10
NEGATIVE
PROBE
POSITIVE
PROBE
+12 -12 GND
+5 SLH SLL
CHASSIS
GND
*MTA42
6
1
Board # =
*
ESPS and ESPS2 ARE DIFFERENT. TAKE CARE TO NOT
MIX UP PART NUMBERS. IF WRONG POWER SUPPLY
IS USED PERMANENT BOARD DAMAGE WILL OCCUR.
48040H7R/K - 48040M7K
PELLERIN MILNOR CORPORATION
L
1
L
2
L
3
TB
MVLF
EXHV
INVERTER
FLT
TBV
CSVS
CB1
AUX
CSDO
MVRTR
MVINV
ETVS
WCL
WCI
ETDO
EFP
1
EF
0
1
EFP
2
EF
0
2
B2T2015005
2017355A
INCOMING POWER
SEPERATE BRANCH CIRCUIT PROTECTION
COPPER CONDUCTORS ONLY
31
Summary of Contents for 48040H7K
Page 2: ......
Page 4: ......
Page 27: ...This page intentionally left blank 23 ...
Page 30: ...26 ...
Page 31: ...27 ...
Page 38: ...34 ...
Page 39: ...35 ...
Page 40: ...36 ...
Page 41: ...37 ...
Page 42: ...38 ...
Page 43: ...39 ...
Page 44: ...40 ...
Page 45: ...41 ...
Page 46: ...42 ...
Page 47: ...43 ...
Page 48: ...44 ...
Page 49: ...45 ...
Page 50: ...46 ...
Page 51: ...47 ...
Page 52: ...48 ...
Page 53: ...49 ...
Page 54: ...50 ...
Page 55: ...51 ...
Page 56: ...52 ...
Page 57: ...53 ...
Page 58: ...54 ...
Page 59: ...55 ...
Page 60: ...56 ...
Page 61: ...57 ...
Page 62: ...58 ...
Page 63: ...59 ...
Page 64: ...60 ...
Page 65: ...61 ...
Page 66: ...62 ...
Page 67: ...63 ...
Page 68: ...64 ...
Page 69: ...65 ...
Page 70: ...66 ...
Page 71: ...67 ...
Page 72: ...68 ...
Page 73: ...69 ...
Page 74: ...70 ...
Page 75: ...71 ...
Page 76: ...72 ...
Page 77: ...73 ...
Page 78: ...74 ...
Page 79: ...75 ...
Page 80: ...76 ...
Page 81: ...77 ...
Page 82: ...78 ...
Page 83: ...79 ...