Chapter 3. Routine Maintenance
PELLERIN MILNOR CORPORATION
Table 6: Bearings and Bushings. See
Table 7
for Motors.
Apply grease to these components to prevent damage.
Mark
1
2
3
4
5
6
Do this each
Component
More Data. See also
Section 3.1.4
“Lubricant Identification and Procedures”
x
600 hours
bearing housing
The bearing assembly is oil-filled. No routine
grease maintenance is required. Grease is
added to the seal grease cavity at assembly.
Examine the grease cavity drain tube (
Figure
14
). If a large quantity of contamination or
water flows from the tube, maintenance can
be necessary. Speak to your dealer or
Milnor.This is not routine maintenance.
Table 7: Motor Grease Schedule. Use the data in
Section 3.1.4.2
to complete this table.
Interval
Quantity
Dates When Grease is Added
Motor Identification
(example: main drive)
Years
Hours
fl oz
mL
.
Table 8: Mechanisms and Settings
Make sure mechanisms are serviceable and settings are correct to prevent unsatisfactory
performance.
Mark
1
2
3
4
5
6
Do this each
Component
More Data
x
2400 hours
controller circuitry
Examine wiring and connections in electrical
boxes. Look for corrosion, loose connections.
See
Section 3.1.3
x
200 hours
bath level sensor that uses air
pressure
Examine the air tube and connections. See
Figure 11
23
Summary of Contents for 30022V8Z
Page 2: ......
Page 4: ......
Page 5: ...English 1 1 ...
Page 6: ......
Page 37: ...Türk 2 33 ...
Page 38: ......
Page 68: ......
Page 69: ...Español 3 65 ...
Page 70: ......
Page 101: ...Français 4 97 ...
Page 102: ......
Page 136: ......
Page 137: ...Dansk 5 133 ...
Page 138: ......
Page 169: ...Deutsch 6 165 ...
Page 170: ......