Chapter 4. Testing and Troubleshooting
PELLERIN MILNOR CORPORATION
Figure 16: Viewing Inputs in
Attendant
Mode
Left Digit of
Minutes
Remaining
Display
Right Digit of
Minutes
Remaining
Display
Legend
.
0.
Clutch (MTA3-9)
1.
Door not locked (MTA3-
2)
2.
Coin count (MTA3-3)
3.
Inverter OK (MTA3-4)
4.
Door closed (MTA3-5)
5.
not used (MTA3-6)
6.
Level made (MTA3-7)
7.
Vibration switch tripped
(MTA3-8)
8.
Select
button
9.
Start
button
10.
Attendant
switch
11.–15.
not used
Table 7: Input Signals
Signal Name
Connector
Pin
Function
Brake
9
brake is engaged
Door not locked
2
door latch is unlocked
Coin count
3
coin drop activated
Inverter OK
4
inverter reports normal operation
Door closed
5
door is closed
—not used—
6
—
Level made
7
level is achieved
Vibration
MTA3
8
vibration switch tripped
Attendant switch
serial
control panel switch closed
Select button
serial
Select button pressed
Start button
MTA2
serial
Start button pressed
The status of micro-controller inputs can only be viewed if the machine is idle (not running a
formula) and the door is closed.
Display or Action
Explanation
With power present at the machine, insert the key in the
Attendant
switch and turn the switch from the vertical to the
horizontal position.
Note 8:
The key cannot be removed from the
Attendant
switch while the switch is in the
Attendant
(horizontal) position. Turn the switch to the
normal
(vertical) position to release the key.
Display or Action
Explanation
starts the formula that was selected before the
Attendant
switch was turned to
the horizontal position.