![Milltronics XPS-10 Instruction Manual Download Page 8](http://html1.mh-extra.com/html/milltronics/xps-10/xps-10_instruction-manual_1797015008.webp)
Page 8
XPS 10/15 F Series Transducer
PL-551
Specifications
XPS 15 F Series Transducers
Measurement Range:
{
0.45 – 15m (1.5 – 50ft)
Frequency:
{
43kHz
Beam Angle:
{
6°
Environmental
{
location:
{
indoor/outdoor
{
altitude:
{
2000m maximum
{
ambient temperature:
{
-20 to 95°C (-4 to 203°F)
{
pollution degree:
{
4
Construction
{
exposure:
{
Kynar
®3
{
colour:
{
slate gray
{
mounting:
{
1” NPT conduit connection
{
options:
{
factory flange to suit ANSI standard
{
submergence shield, where flooding can occur
{
split flange for field mounting to suit ANSI
{
cable:
{
2-wire shielded / twisted, 0.5 mm
2
(20 AWG) PVC
jacket
Supply Source
{
Transducer shall only be supplied by a Milltronics certified controller.
Weight
4
{
2.0 kg (4.4lb)
Separation
{
365m (1200ft) from transducer
Approvals
{
FM Class 1 Div 1, Group A, B, C and D
{
FM Class 2 Div 1, Group E, F, and G
{
see nameplate or consult Milltronics for other current approvals
3
Kynar
®
is registered trade mark of ELF Atochem
4
approximate shipping weight of transducer with standard cable length