About the CVCC

The CVCC (Current to Voltage Communication Converter) is a passive communication link 
used to interface Milltronics equipment using proprietary 20 mA bipolar communication 
format with RS-232C or RS-422 communication of a customer’s computer.

Transmissions that enter the CVCC will cause the front panel LED’s to flash, providing a 
visual indication that communication through the CVCC is being achieved. The messages 
are passed through without interpretation or modification of the message. The CVCC 
simply converts the signal level from RS-232C/RS-422 to 20 mA current loop or vice versa.

Installation

1.

Take off the top cover by removing the four upper screws.

2.

Connect data link from the Milltronics equipment. Refer to Interconnection.

3.

Connect data link from the customer’s computer. Refer to Interconnection.

4.

Check power input jumpers for standard 115/230 Vac or special 100/200 Vac 

operation. Refer to Interconnection or board silkscreen.

5.

Connect power. Refer to Interconnection or board silkscreen.

6.

Flip power switch to ON.

7.

Replace cover and secure.

cvccfinal.fm  Page 2  Thursday, September 6, 2001  2:17 PM

Summary of Contents for CVCC

Page 1: ...CVCC CURRENTVOLTAGE COMMUNICATION CONVERTER September 2001 OMMUNICATION CONVERTE Instruction Manual ...

Page 2: ...on and in electronic version We encourage users to purchase authorized bound manuals or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments Inc Siemens Milltronics Process Instruments Inc will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions While we have verified the contents of this manual for...

Page 3: ...oop bidirectional cable Belden 9552 two pair shielded twisted 18 ga RS 232C bidirectional cable Belden 9552 two pair shielded twisted 18 ga cable length 15 m 50 ft maximum RS 422 bidirectional cable Belden 9553 three pair shielded twisted 18 ga cable length 15 m 50 ft maximum Operating Temperature 20 to 60 C 5 to 140 F Weight 2 7 Kg 5 lb Enclosure general purpose 203 mm 8 W x 254 mm 10 D x 84 mm 3...

Page 4: ...eved The messages are passed through without interpretation or modification of the message The CVCC simply converts the signal level from RS 232C RS 422 to 20 mA current loop or vice versa Installation 1 Take off the top cover by removing the four upper screws 2 Connect data link from the Milltronics equipment Refer to Interconnection 3 Connect data link from the customer s computer Refer to Inter...

Page 5: ...7ML19981FG01 CVCC INSTRUCTION MANUAL Page 3 CVCC Outline Cable Entry REAR View power signal 254 mm 10 C V C C 203 mm 8 84mm 3 3 ...

Page 6: ...Page 4 CVCC INSTRUCTION MANUAL 7ML19981FG01 Board Layout ...

Page 7: ...fer to the associated product manuals for details on terminal connections Connect shield at only one end L 2 G L V 5 P N I 2 3 2 S R D L E I H S N I 2 2 4 S R N I Y S I A D M O C T U O Y S I A D T U O 2 3 2 S R T U O 2 2 4 S R V 2 1 N M O C E V I E C E R D L E I H S T I M S N A R T 1 V AC 230 VAC 115 VAC 115 R N 1 1 2 3 4 5 6 7 8 9 10 111213 141516 1718 1920 2122 232425 TB1 note 3 SW 4 FUSE 3 2 7 ...

Page 8: ... wire a jumper across TB1 terminals 20 to 21 only Refer to board silkscreen 4 Refer to associated product manuals for details on terminal connections Connect shield at only one end L 2 L G V 5 P N I 2 3 2 S R D L E I H S N I 2 2 4 S R N I Y S I A D M O C T U O Y S I A D T U O 2 3 2 S R T U O 2 2 4 S R V 2 1 N M O C E V I E C E R D L E I H S T I M S N A R T 1 V AC 230 VAC 115 VAC 115 R N 1 1 2 3 4 ...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...C C 7ML19981FG01 ...

Reviews: