Millipore SDS 200 User Manual Download Page 3

 

Notice 

The information in this document is subject to change without notice and should not be construed as a commitment by Millipore 

SAS. Millipore SAS assumes no responsibility for any errors that might appear in this document. This manual is believed to be 
complete and accurate at the time of publication. In no event shall Millipore SAS be liable for incidental or consequential 

damages in connection with or arising from the use of this manual. 

We manufacture and sell water purification systems designed to produce pure or ultrapure water with specific characteristics 
(

µ

S/cm, T, TOC, CFU/ml, Eu/ml) when it leaves the water purification system provided that the systems are fed with water quality 

within specifications, and properly maintained as required by the supplier. 

We do not warrant these systems for any specific applications. It is up to the end user to determine if the quality of the water 

produced by our systems matches his expectations, fits with norms/legal requirements and to bear responsibility resulting from 
the usage of the water. 

Copyright 

 2012 Millipore SAS. Printed in France. All rights reserved. This book or parts thereof may not be reproduced in any form 

without the written permission of the publishers. The photos are non-contractual. 

PF08837 - V3.0 – 12/2012 

Manufacturer: MILLIPORE SAS, 67120 MOLSHEIM, FRANCE. 

Trademarks 

Elix is a registered trademark of Merck KGaA, Darmstadt, Germany. 

RiOs, Merck Millipore and the M logo are trademarks of Merck KGaA, Darmstadt, Germany. 
All other trademarks are trademarks of their respective owners. 

Summary of Contents for SDS 200

Page 1: ...User Manual SDS 200 SDS 350...

Page 2: ......

Page 3: ...ed with water quality within specifications and properly maintained as required by the supplier We do not warrant these systems for any specific applications It is up to the end user to determine if t...

Page 4: ...at a location that handles discarded electric or electronic equipment Proper disposal of equipment containing electric or electronic components will help to reduce pollution effects to the environment...

Page 5: ...NS 6 Dimensions and Weight 6 Electrical Specifications 7 Environmental Specifications 7 Hydraulic Specifications 7 Pump Performance 8 CHAPTER 3 USING THE SDS 9 3 1 DEFAULT SETTING 9 3 2 PROGRAMMING TH...

Page 6: ......

Page 7: ...If this manual is not the correct one for your SDS 200 or SDS 350 then please contact Millipore SAS INSTALLATION INFORMATION IMPORTANT INSTALLATION INSTRUCTIONS ARE NOT INCLUDED INSTALLATION OF THIS P...

Page 8: ...te that proper safety equipment has to be used Protective glasses and gloves must be worn This UV RADIATION sticker is used to refer to a position on the water system Cabinet or inside of it where exp...

Page 9: ...n loop The purified water is generally produced by reverse osmosis or by continuous deionisation DIFFERENT VERSIONS OF SDS The table below shows the main components which come with the SDS COMPONENTS...

Page 10: ...e ordered separately Plugged outlet Pressure gauge Reservoir access lid Sanitary overflow Front cabinet Switch ON OFF panel Water level sensor Isolating valve on feed line to pump Pump outlet Drain tu...

Page 11: ...in a flow diagram A description of each item is below ITEM FUNCTION Inlet Where purified water enters into the SDS Level sensor A device that measures the water level in the reservoir in full liters o...

Page 12: ...owing pump outlet pressure FUSE HOLDER Main fuse POWER ON OFF Main power switch 2 4 TECHNICAL SPECIFICATIONS DIMENSIONS AND WEIGHT SDS 200 SDS 350 SDS 200 SDS 350 Operating weight 260 Kg 430 Kg Dry we...

Page 13: ...e Millipore SAS Spare Part FTPF00756 230V 10 50Hz 800 VA with pump TANK5P200 TANK5P350 3 15 A T fuse Millipore SAS Spare Part FTPF03213 230V 10 50Hz 10 VA without pump TANK50200 TANK50350 0 5 A T fuse...

Page 14: ...Product Information SDS 200 SDS 350 8 PUMP PERFORMANCE 30 liters min at 3 bar pressure Flow rate gal min Pressure psi Pressure bar Flow rate l min 115 V 230 V...

Page 15: ...ump please read the procedures below for programming the pump running times 3 2 PROGRAMMING THE SDS HOW TO GET IN THE DIST SETUP MODE The DIST SETUP Menu shows you all the SDS functions S T A ND B Y S...

Page 16: ...T P R O G A S M C Y C L E D A Y A L L D A Y S S T A R T 0 0 h 0 0 S T O P 0 0 h 0 0 R E C I R C 0 1 m i n h Press on DIST PROG DAY Choose a specific day of a week Monday Tuesday etc you want the DIST...

Page 17: ...ic Acid solution of pH 2 equivalent to Normality 0 01 N Add some pH indicator so a colour change can be seen if the pH rises to a value such as 4 This will indicate that it is time to renew the acidic...

Page 18: ......

Page 19: ...S 200 Tank 200L Tank only TANK00200 SDS 350 Tank 350L Tank only TANK00350 SDS tank RiOs vent filter 0 22 Aervent TANKVNT01 SDS tank Elix vent filter 0 22 Aervent carbon and soda lime TANKVNT02 ASM Aut...

Page 20: ......

Page 21: ...NK7P200 TANK7P350 10 A T fuse Millipore SAS Spare Part FTPF04803 100V 10 without pump TANK70200 TANK70350 1 A F fuse Millipore SAS Spare Part FTPF00756 115V 10 with pump TANK6P200 TANK6P350 10 A T fus...

Page 22: ...ter Ordering Information Accessories bag including 2 fittings F 20M hose barb 1 elbow fitting F 20M hose barb 5 m long tube 19x27 5 mm Vent filter this accessory is not delivered with the systems and...

Reviews: