OM-248663 Page 17
7-5.
Troubleshooting Table
!
Disconnect power before troubleshooting.
Trouble
Remedy
No wire feed at gun, feeder not operat-
ing. Check motor or brake solenoid.
Reset circuit breaker at power source. See power source owner’s manual.
Replace trigger-switch and test operation.
Check trigger-switch wires for continuity.
No wire feed at gun, feeder operating
properly.
Reset circuit breaker in feeder/control box and check for short in motor leads. See feeder/control owner’s
manual.
Check potentiometer with meter and replace if necessary.
Check motor and potentiometer wires for continuity.
See feeder/control owner’s manual.
Wire feeds, but welding wire is not ener-
gized.
Clean and tighten all power connections.
See feeder/control owner’s manual.
Check operation of welding power source.
Wire feeds erratically.
Check conduit for wear and obstruction and replace if necessary.
Check contact tip for correct size and replace if necessary.
Check pressure roll tension setting (see Section 6-2).
Check for proper head tube liner (see Table 9-7).
Wire feeds one speed only.
Check potentiometer with meter and replace if necessary.
Check continuity of welding gun wire feed speed potentiometer and replace if necessary.
See feeder/control owner’s manual.
Pressing gun trigger does not energize
feeder. Welding wire is not energized.
Shielding gas does not flow.
Secure plug from gun control cable into gun control receptacle on feeder.
Have nearest Factory Authorized Service Agent check optional water flow switch, if applicable.
Wire feeds, shielding gas flows, but
welding wire is not energized.
See Troubleshooting section in welding power source manual.