U s e r I n s t r u c t i o n s - E n g l i s h
8
4.3 System Replacement Parts
Part
No.
Component
Description
TRTB
Top Bracket Assembly
5 ft. (1.5m) galvanized steel bracket (1-1/2” x 1-1/2” tube) includes inline shock absorber with shackle, two rung clamp
assemblies (each w/4-hole mounting plate for 1-1/2" tube, two 3/8"-16 x 1-5/8" x 3-1/2" U-bolts, four 3/8" lockwashers, and
four 3/8"-16 hex nut fasteners), and bottom rung clamp assembly (w/3/8"-16 x 1-5/8" x 3-1/2" U-bolt, two 3/8" lockwashers,
two 3/8"-16 hex nut fasteners and two fastener caps).
TRTB-7
7 ft. (2m) Top Bracket
Assembly
7 ft. (2m) galvanized steel bracket (2” x 2” tube) includes inline shock absorber with shackle, two rung clamp assemblies
(each w/4-hole mounting plate for 2" tube, two 3/8"-16 x 1-5/8" x 3-1/2" U-bolts, four 3/8" lockwashers, and four 3/8"-16 hex
nut fasteners), and bottom rung clamp assembly (w/two 3/8"-16 x 4" bolts, two 3/8" flat washers, 2-hole mounting plate,
two 3/8" lockwashers, and two 3/8"-16 hex nut fasteners).
TRTB-10
10 ft. (3m) Top Bracket
Assembly
10 ft. (3m) galvanized steel bracket (2” x 2” tube) includes inline shock absorber with shackle, two rung clamp assemblies
(each w/4-hole mounting plate for 2" tube, two 3/8"-16 x 1-5/8" x 3-1/2" U-bolts, four 3/8" lockwashers, and four 3/8"-16 hex
nut fasteners), and bottom rung clamp assembly (w/two 3/8"-16 x 4" bolts, two 3/8" flat washers, 2-hole mounting plate,
two 3/8" lockwashers, and two 3/8"-16 hex nut fasteners).
TRRCA
Extra Rung Clamp Assembly
(for 5 ft. top bracket)
Includes 4-hole mounting plate for 1-1/2" tube, two 3/8"-16 x 1-5/8" x 3-1/2" U-bolts, four 3/8" lockwashers, and four 3/8"-
16 hex nut fasteners
TRRCA-10
Extra Rung Clamp Assembly
(for 7ft. & 10 ft. top brackets)
Includes 4-hole mounting plate for 2" tube, two 3/8"-16 x 1-5/8" x 3-1/2" U-bolts, four 3/8" lockwashers, and four 3/8"-16
hex nut fasteners
TRLL
Cable Lifeline
3/8” diameter galvanized steel cable with thimble. Various lengths available.
TRQL
Quick Link
Galvanized steel quick-link used for connecting cable to shackle on inline shock absorber.
VGCG
Automatic Pass-Through
Cable Guide
Galvanized steel cable guide bracket includes M10-1.5mm x 1-1/2" x 2-9/16" U-bolt, two M10 flat washers and two M10-
1.5mm locknuts.
TRCG
Manual Pass-Through
Cable Guide
Galvanized steel cable bracket with convertible polyurethane cable retainer head includes 3/8"-16 x 1-1/4" x 2" U-Bolt, two
3/8" lockwashers, two 3/8"-16 hex nuts, two 1/4"-20 x 1-1/4" bolts, four 1/4" flat washers, and two 1/4"-20 locknuts.
TRBB
Bottom Bracket Assembly
Galvanized steel bracket (1-1/2” x 1-1/2” tube) includes rung clamp assembly (w/4-hole mounting plate for 1-1/2" tube, two
3/8"-16 x 1-5/8" x 3-1/2" U-bolts, four 3/8" lockwashers, and four 3/8"-16 hex nut fasteners), bottom rung clamp assembly
(w/two 3/8"-16 x 3" bolts, two 3/8" flat washers, 2-hole mounting plate, two 3/8" lockwashers, and two 3/8"-16 hex nut
fasteners), and tensioning rod assembly (w/compression spring, two saddle clips, 7/16" washer, and six 7/16"-14 hex nut
fasteners).
Model
No.
Cable Sleeve
VGCS
Vi-Go Automatic Pass-Through Cable Sleeve [Also available with carabiner (VGCS-C) or with integral swivel and carabiner (VGCS-SC)]
TRCS
Vi-Go Manual Pass-Through Cable Sleeve [Also available with carabiner (TRCS-C) or with integral swivel and carabiner (TRCS-SC)]
5.0 System Installation
• Before installation, carefully inspect all components of the system according to the manufacturer’s instructions
(see 8.0 Inspection and Maintenance). Do not use if there are any damaged or missing parts (see 4.3 System
Replacement Parts).
• Ensure that the structure/ladder on which the Vi-Go System is to be affixed is capable of withstanding loads
resulting from a fall (see 3.0 System Requirements).
• For ease of installation, the Vi-Go Installation Kit (TRIK)
may be purchased
separately. Contact your Miller distributor.
WARNING: Personal fall protection is required during installation.
Persons installing the system must use caution and shall not be ex-
posed to a fall hazard during the installation procedure. Do not con-
nect to any component of a partially installed system.
System Installation Overview: The recommended installation procedure of the Vi-Go Vertical Cable Lifeline Sys-
tem is to install from the top of the ladder down.
Tools Required for Installation: Torque wrench, standard sockets--7/8" and 3/4", deep socket--9/16", standard
wrenches--7/16", 11/16" and 3/4", crowfoot wrench--17mm (for part VGCG only), cable cutters--minimum 3/8"
capacity needed (5/8" capacity preferred), and a tape measure.
TRIK